vi
Installation and User’s Guide
IMPORTANT SAFETY PRECAUTIONS
(continued)
General Installation Information
1.
Installation and service must be performed by a qualified installer or service agency, and must conform to all
national, state, and local codes.
2.
UltraTemp
®
heat pumps get electrical power from an external source and provide a dual electronic thermostat
control system for pool/spa combinations or preheat convenience.
3.
This heat pump is specifically designed for heating fresh water swimming pools and spas. Do not use it as a
general service heater. Consult your dealer for the appropriate Pentair Water products for these applications.
General Specifications
Installation Location Certified for use:
OUTDOOR USE ONLY. Failure to provide the proper clearances outlined on page 5 will lower the
performance of the heat pump and void the warranty.
Water Pipe/Heater Connection —
Plastic 2” PVC (Unions included)
Flow Rate
Maximum 100 gpm [380 lpm]
Minimum 30 gpm [110 lpm]
Maximum Working Water Pressure 50 psi
Electrical Supply
– Voltage Requirements:
110
120
120 H/C
120C
100I
90I
Voltage/Phase/Hz
208-230/1/60
208-230/1/60
208-230/1/60
208-230/3/60
230/3/60
380-400/3/50
Min. Circuit Ampacity
42
42
42
35
42
18
Recommended Fuse Size
50
50
50
50
50
30
Max. Fuse Breaker Size
70
70
70
60
60
40
Compressor/Fan Motor/System RLA
32/2/34
32/2/34
32/2/34
26/2/28
32/2/34
12/1/13
Compressor/Fan Motor/System LRA
148/4/152
185/4/189
185/4/189
190/4/194
130/4/134
87/3/90
Compressor/Fan Motor/System MCC
50/NA/NA
50/NA/NA
50/NA/NA
39/NA/NA
50/NA/NA
19/NA/NA
Capacity (Btu/h) 80A-80RH-80W *
108,000
125,000
125,000
125,000
102,000
85,000
COP 80A-80RH-80W *
5.8
5.5
5.4
6.1
5.9
5.7
Power Input, KW (80A-80RH-80W) *
5.5
6.7
6.8
6.0
5.1
4.4
Current, Amp (80A-80RH-80W) *
25
30
31
19
25
9
Capacity (Btu/h) 80A-63RH-80W **
101,000
117,000
117,000
115,000
96,000
81,000
COP 80A-63RH-80W **
5.5
5.3
5.2
5.8
5.6
5.4
Power Input, KW (80A-63RH-80W) *
5.4
6.5
6.6
5.8
5.0
4.4
Current, Amp (80A-63RH-80W) *
25
29
30
18
24
9
Capacity (Btu/h) 50A-63RH-80W ***
72,000
82,000
82,000
81,000
67,000
56,000
COP 50A-63RH-80W ***
4.0
4.0
4.0
4.3
4.0
4.0
Power Input, KW (50A-63RH-80W) *
5.3
6.0
6.0
5.5
4.9
4.1
Current, Amp (50A-63RH-80W) *
24
27
27
17
24
9
Shipping Weight (lbs)
270
270
278
280
280
250
Shipping Size (LxWxH)
38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x41.5" 38.7"x33.3"x33.5"
* 80A-80RH-80W: 80° F. Air Temp., 80% Relative Humidity [RH], 80° F. Water Inlet Temp.
** 80A-63RH-80W: 80° F. Air Temp., 63% Relative Humidity [RH], 80° F. Water Inlet Temp.
*** 50A-63RH-80W: 50° F. Air Temp., 63% Relative Humidity [RH], 80° F. Water Inlet Temp.
COP = Coefficient of Performance
Models
UltraTemp
®