Troubleshooting guide

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the EnviroMAX 1500 

Variable Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs 

have all turned off. At this point, reconnect power to the pump. If the error has not cleared then proper 

troubleshooting will be required. Use the error description table below to begin troubleshooting.

 – 

Communication Link between the HMI and Motor control has been lost:

 Check the jacketed wire on

the back side of the keypad inside the drive top cover. Ensure that the 5 pin connector is properly plugged 

into the socket and that there is no damage to the cable.

 – 

Power Module over current detected:

 If this error displays multiple times, then there may be a 

problem with the pump’s rotating assembly. Please disassemble the pump and investigate to see if there 

is a problem with the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for 

disassembling the pump.

 – 

Absolute AC Under Voltage Detected:

 This indicates that the supply voltage has dropped below the

operating range of 99v. This could be caused by normal voltage variation and will clear itself. Otherwise 

therecould be excess voltage sag caused by improper installation or improper supply voltage.

– 

Internal Errors:

 These errors can occur based on operating conditions

and the UL 60730 required self-diagnostic safety software. If they do not clear after multiple restart 

attempts the drive should undergo a hard power cycle. Disconnect main power by turning off the breaker 

long enough for the keypad LEDs to turn off. After power is reconnected if one of these errors continues to 

reappear, the drive may need service.

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

17

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

Troubleshooting (Cont.)

Problem

Possible Cause

Corrective Action

Pump runs without flow.

Impeller is loose

Air leak
Clogged or restricted plumbing

Check that pump is spinning by looking at fan on back 
of SuperFlo VS Variable Speed Pump. If so, check 
that pump impeller is correctly installed.
Check plumbing connections and verify they are tight.
Check for blockage in strainer or suction side piping.
Checked for blockage in discharge piping including 
partially closed valve or dirty pool filter.

Errors and Alarms

If an alarm is triggered the drive’s LCD screen will display the fault code text and the SuperFlo

®

 VS Variable 

Speed Pump will stop running. Disconnect power to the pump and wait until the keypad LEDs have all turned 
off.  At this point, reconnect power to the pump.  If the error has not cleared then proper troubleshooting will be 
required.  Use the error description table below to begin troubleshooting.



 – Communication Link between the HMI and Motor control has been lost

: Check the jacketed wire on 

the back side of the keypad inside the drive top cover.  Ensure that the 5 pin connector is properly plugged into 
the socket and that there is no damage to the cable.



 – 

Power Module over current detected

: If this error displays multiple times, then there may be a problem 

with the pump’s rotating assembly.  Please disassemble the pump and investigate to see if there is a problem with 
the impeller or mechanical seal. See page 14 “Pump Disassembly” for instructions for disassembling the pump.



 – 

Absolute AC Under Voltage Detected

: This indicates that the supply voltage has dropped below the 

operating range of 99v.  This could be caused by normal voltage variation and will clear itself.  Otherwise there 
could be excess voltage sag caused by improper installation or improper supply voltage.



,















 –

 Internal Errors: 

These errors can occur based on operating conditions 

and the UL 60730 required self-diagnostic safety software.  If they do not clear after multiple restart attempts the 
drive should undergo a hard power cycle.  Disconnect main power by turning off the breaker long enough for the 
keypad LEDs to turn off.  After power is reconnected if one of these errors continues to reappear, the drive may 
need service.

Fault Code

Description



Communication link between HMI and motor control has been lost



Power Module over current detected



Phase Current Offset out of range



Phase Current Imbalance detected



Absolute AC under voltage detected



Absolute Phase current limit exceeded



Absolute Diode Bridge temperature limit exceeded



Absolute Power Module temperature limit exceeded



Absolute Power Factor Correction (PFC) temperature limit exceeded



DC bus over voltage detected



DC bus under voltage detected

,

,

,

,

,

,

,

23

Troubleshooting

Содержание Sta-rite EnviroMAX 1500

Страница 1: ...Variable Speed Pool Pump...

Страница 2: ...available When you see the Eco Select brand on one of our products you ll know it is our greenest and most efficient product in that equipment category These products do the best job of saving energy...

Страница 3: ...6 Pool Outlets 6 Electrical 7 Equipotential Bonding 7 Operation Priming the Pump 9 Control Panel Overview 10 Setting Clock 11 Using Default Schedule 11 Custom Schedules 12 Operating the Pump While Ru...

Страница 4: ...rotected motor prevents damage by automatically shutting down the motor in the event of a locked rotor under voltage over voltage or over current condition and will automatically reduce the speed duri...

Страница 5: ...ing IPX6 Inlet Suction ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Max Total Head 21m Max Working Pre...

Страница 6: ...0 2 4 6 8 10 12 14 16 18 20 22 Head m Flow L min 3 1 5 0 R P M 2850RPM 2600RPM 2400RPM 2200RPM 2000RPM 1800RPM 1600RPM 1400RPM 1200RPM 0 50 100 150 200 250 300 350 400 450 500 550 600 650 279mm 515mm...

Страница 7: ...ion 200sq cm min inlet outlet and air circulation Allow 200mm to keep rear of motor clear b Have adequate floor drainage to prevent flooding and be protected from excess moisture c Be solid level rigi...

Страница 8: ...ly to the pump Additionally if a suitable socket outlet is not available a weatherproof socket must be installed by an electrician in a suitable location RCD tripping indicates an electrical problem I...

Страница 9: ...metal piping in accordance with the wiring rules Run a wire from the equipotential bonding terminal on the pump bottom left motor bolt with serrated washer to the pool bonding structure Figure 1 Bondi...

Страница 10: ...cate the oring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes i...

Страница 11: ...e Speed Pump Installation and User s Guide If power is connected to the SuperFlo VS Variable Speed Pump motor pressing any of the following buttons referred to in this section could result in the moto...

Страница 12: ...must be pressed and the LED lit for the pump to run 7 OPERATING THE PUMP etting the Clock When the pump is first plugged in the clock will blink o indicate that is has not been set Any daily schedule...

Страница 13: ...ill run the custom user programmed schedule 2 00 Figure 5 Setting Duration 8 SUPERFLO VS Variable Speed Pump Installation and User s Guide Custom Schedules To customize the run schedule for your Super...

Страница 14: ...custom user programmed schedule Note If the pump has been stopped via the Start Stop button the pump will not run until the pump is turned back on by the Start Stop button If the Start Stop LED is ill...

Страница 15: ...ick Clean prior to the duration being completed you can press and hold the Quick Clean button for 3 seconds and the pump will return to the appropriate point in the programmed schedule If power is con...

Страница 16: ...le through the following things PrI Priming Speed PrI Remaining Time Once priming has begun the speed can be adjusted between 3450 and 1700 RPM using the and arrows If it is adjusted below 1700 RPM Pr...

Страница 17: ...the motor can still be stopped by pressing the Start Stop button However the motor can not be started again until the user unlocks the keypad Keypad Lockout Key lockout will not prevent the motor fro...

Страница 18: ...ns Also write down the Priming Speed 3 Press and hold the 1 2 3 and Quick Clean buttons for 3 seconds 4 The screen will display FACt rSt if factory reset is successful See Figure 13 5 Be sure to repro...

Страница 19: ...4 shows one of many potential wiring options available to the installer allowing you to install External Controls in the way that best suits your needs Note This 5V Signal red wire is output from the...

Страница 20: ...solved by this priority Quick Clean Speed 3 Speed 2 and then Speed 1 External Control Only Mode External Control Only mode will only allow the pump to run from external controls inputs When this mode...

Страница 21: ...leaves or debris which could become a fire hazard or choke the motor fan Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal Call a Pentai...

Страница 22: ...p from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer ve...

Страница 23: ...section of this manual Reset to default if necessary Motor high temperature limit exceeded Ensure motor fins are clean and fan is intact and free from blockages Ensure adequate ventilation and reduce...

Страница 24: ...mproper supply voltage Internal Errors These errors can occur based on operating conditions and the UL 60730 required self diagnostic safety software If they do not clear after multiple restart attemp...

Страница 25: ...24 Replacement Parts 4 3 5 11 12 1 10 2 13 15 16 14 8 7 6 9 9a 9b 9c 9d...

Страница 26: ...See Pump Fasteners Kit PUMP FASTENERS KIT 1 801280 9 PUMP CASING ASSEMBLY C176 71P 9a LID 1 17307 0111 9b O RING LID 1 35505 1440 9c BASKET 1 C8 58P 9d DRAIN PLUG O RING 2 U178 920P 10 O RING PUMP CA...

Страница 27: ...26 Notes...

Страница 28: ...664 266 Email au sales pentair com Web www pentairpool com au Information contained here in remains the property of Pentair Australia Pty Ltd Any reproduction display publication modification or dist...

Отзывы: