Priming will automatically run when the EnviroMAX 1500 Variable Speed Pump is started from a stopped 

state, except when running in Quick Clean mode. Priming will run at 3450 RPM by default, and will last for 

5 minutes. The drive’s screen will display and cycle through the following things “PrI - Priming Speed, PrI 

-- Remaining Time”.

Once priming has begun, the speed can be adjusted between 3450 and 1700 RPM using the “

+

” and “

-

” 

arrows. If it is adjusted below 1700 RPM, Priming mode will be disabled and the pump will immediately 

begin to run the scheduled speed.

When priming is disabled and the pump is started from a stopped state, the screen will display, “PrI - OFF” 

for 10 seconds while running the scheduled speed (See 

Figure 6

). This allows the user time to enable 

priming mode by pressing the “

+

” arrow. If the user chooses to re-enable priming mode, the pump will 

then transition from the scheduled speed to 1700 RPM. The user can increase the priming speed from 

1700 RPM by pressing the “

+

” arrow. The 5 minute priming countdown timer starts when priming is first 

engaged.

The installer should set the priming speed to be sufficient for priming the pump from a fresh install, 

but not so fast that there is a substantial waste of energy during the 5 minute priming window. The time 

the pump needs to achieve prime can change based on local environmental conditions such as water 

temperature, atmospheric pressure, and your pool’s water level. All of these things should be taken into 

consideration when setting the priming speed, however in most cases the pump will not need to run at 

3450 RPM to successfully prime itself.

Please test and verify chosen priming speeds more than once, letting the water drain from the system in 

between each test.

Note: 

The pump strainer basket should always remain full to the bottom of the inlet in order to prevent air 

from entering the system.

The EnviroMAX 1500 Variable Speed Pump is equipped with a Quick Clean feature, which can be engaged 

to temporarily run at higher or lower speeds ranging between 300 to 3450 RPM. Once the Quick Clean 

duration has elapsed, the pump will automatically return to the programmed schedule.

Programming Quick Clean:

1. Stop the pump if it is running by pressing the 

Start/Stop

 button.

 

2. Press the 

Quick Clean 

button. The LED above the 

Quick Clean

 button and the “Speed” parameter LED 

will flash while editing. See 

Figure 7

.

Quick Clean

10

 

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

This pump is shipped with Priming mode ENABLED. Unless the Priming settings are changed in the menu, 

be aware 

that the pump will speed up to the priming speed when the pump is powered on for the first time, and the 

start/stop button is pressed.

Before turning the pump ON, be sure the following conditions are met: 

1. Open filter air relief valve. 

2. Open valves. 

3. Pool return is completely open and clear of any blockages. 

4. Water in the pump basket.

5. Stand clear of the filter or other pressurized vessels.

DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. 

If this occurs, the damaged seal must be replaced.  ALWAYS maintain proper water level in your pool (half way up 

skimmer opening). If the water level falls below the skimmer opening, the pump will draw air through the skimmer, losing the prime and 

causing the pump to run dry, resulting in a damaged seal. Continued operation in this manner could cause a loss of pressure, resulting 

in damage to the pump case, impeller and seal and may cause property and personal injury.

Priming will automatically run when the SuperFlo

®

 VS 

Variable Speed Pump is started from a stopped state, 

except when running in Quick Clean mode.  Priming 

will run at 3450 RPM by default, and will last for 5 

minutes.  The drive’s screen will display and cycle 

through the following things “

PrI

 

- Priming Speed,    

PrI

 

-- Remaining Time”.

Once priming has begun, the speed can be adjusted 

between 3450 and 1700 RPM using the “

+

” and “

-

” 

arrows.  If it is adjusted below 1700 RPM, Priming 

mode will be disabled and the pump will immediately 

begin to run the scheduled speed.  
When priming is disabled and the pump is started 

from a stopped state, the screen will display, “

PrI

 

- OFF

” for 10 seconds while running the scheduled 

speed (See 

Figure 10

).  This allows the user time to 

enable priming mode by pressing the “

+

” arrow.  If the 

user chooses to re-enable priming mode, the pump 

will then transition from the scheduled speed to 1700 

RPM.  The user can increase the priming speed from 

1700 RPM by pressing the “

+

” arrow.  The 5 minute 

priming countdown timer starts when priming is first 

engaged. 

The installer should set the priming speed to be 

sufficient for priming the pump from a fresh install, 

but not so fast that there is a substantial waste of 

energy during the 5 minute priming window.  The time 

the pump needs to achieve prime can change based 

on local environmental conditions such as water 

temperature, atmospheric pressure, and your pool’s 

water level.  All of these things should be taken into 

consideration when setting the priming speed, however 

in most cases the pump will not need to run at 3450 

RPM to successfully prime itself. 
Please test and verify chosen priming speeds more 

than once, letting the water drain from the system in 

between each test.  

Note

: The pump strainer basket should always remain 

full to the bottom of the inlet in order to prevent air from 

entering the system.

Figure 6: Priming Deactivation

PrI

OFF

Priming

11

 

SUPERFLO

®  

VS Variable Speed Pump Installation and User’s Guide

Quick Clean

The SuperFlo

®

 VS Variable Speed Pump is equipped 

with a Quick Clean feature, which can be engaged 

to temporarily run at higher or lower speeds ranging 

between 300 to 3450 RPM.  Once the Quick Clean 

duration has elapsed, the pump will automatically 

return to the programmed schedule.

Programming Quick Clean:

1.  Stop the pump if it is running by pressing the 

Start/Stop

 button.

2.  Press the 

Quick Clean 

button.  The LED 

above the 

Quick Clean

 button and the “Speed” 

parameter LED will flash while editing.  See 

Figure 11

.

3.  Use the “

+

” and “

-

” arrows to adjust the speed in 

RPM for Quick Clean.

4.  Press the 

Quick Clean

 button again and the 

display will change to Quick Clean duration.  The 

“Duration” parameter LED will flash while editing. 

See 

Figure 12

.

 

Note: 

The Quick Clean feature does not have a 

start time.

5.  Use the “

+

” and “

-

” arrows to adjust the duration 

in hours and minutes for Quick Clean.

6.  Press the 

Start/Stop 

button and ensure the LED 

is illuminated.  The pump is now on and will run 

the speed and duration set for Quick Clean. 

Note: 

When the Quick Clean duration ends, the pump 

resumes the 24 hour schedule at the point where it 

normally would be running at that time.  The Quick 

Clean duration will not affect the start or stop times 

of the 24 hour schedule.  For example, if Quick Clean 

runs during a period overlapping with a later part of 

SPEED 1 and an early part of SPEED 2, the start time 

of SPEED 3 is not affected.

Note: 

Pressing/Holding Quick Clean key for more than 

three (3) seconds will cancel Quick Clean mode. 

Note: 

During the Quick Clean mode, the pump will not 

start with the priming sequence.

Note: 

It is recommended that you do not set the Quick 

Clean duration to 0 HRS.  Setting the Quick Clean 

duration to 0 HRS will not allow you to change the 

duration setting while the motor is running.  The motor 

will have to be stopped in order to change the Quick 

Clean settings if the duration is set to 0 HRS. 

Keypad Lockout

The SuperFlo VS Variable Speed Pump user interface 

has  a  Keypad  Lockout  feature  to  prevent  unwanted 

changes to the settings.  When locked, the keypad will 

only accept input from pressing the 

Display

 button to 

cycle the displayed information on the screen and input 

to stop the motor from a press of 

Start/Stop 

button.

The keypad can be locked by pressing and holding the 

1” 

button and the 

Quick Clean 

button at the same time 

for at least three seconds.  “

Loc On

” will be displayed if 

successful.
To unlock the keypad press and hold the “

1

” button and 

the 

Quick  Clean 

button  at  the  same  time  for  at  least 

three seconds.  “

Loc OFF

” will be displayed if successful.

Note

: While operating in Keypad Lockout mode the motor 

can still be stopped by pressing the 

Start/Stop 

button. 

However, the motor can not be started again until the 

user unlocks the keypad.

Key lockout will not prevent the motor from being stopped by pressing 

the Start/Stop button. It will then be unable to be restarted until the 

keypad has been unlocked. If the motor is operating in Keypad Lockout 

mode, and being controlled through external controls, it can only run 

when the Start/Stop LED is illuminated.

3450

Figure 7: Setting Speed for Quick Clean

2

:

00

Figure 8: Setting Duration for Quick Clean

15

Operation

Содержание Sta-rite EnviroMAX 1500

Страница 1: ...Variable Speed Pool Pump...

Страница 2: ...available When you see the Eco Select brand on one of our products you ll know it is our greenest and most efficient product in that equipment category These products do the best job of saving energy...

Страница 3: ...6 Pool Outlets 6 Electrical 7 Equipotential Bonding 7 Operation Priming the Pump 9 Control Panel Overview 10 Setting Clock 11 Using Default Schedule 11 Custom Schedules 12 Operating the Pump While Ru...

Страница 4: ...rotected motor prevents damage by automatically shutting down the motor in the event of a locked rotor under voltage over voltage or over current condition and will automatically reduce the speed duri...

Страница 5: ...ing IPX6 Inlet Suction ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Max Total Head 21m Max Working Pre...

Страница 6: ...0 2 4 6 8 10 12 14 16 18 20 22 Head m Flow L min 3 1 5 0 R P M 2850RPM 2600RPM 2400RPM 2200RPM 2000RPM 1800RPM 1600RPM 1400RPM 1200RPM 0 50 100 150 200 250 300 350 400 450 500 550 600 650 279mm 515mm...

Страница 7: ...ion 200sq cm min inlet outlet and air circulation Allow 200mm to keep rear of motor clear b Have adequate floor drainage to prevent flooding and be protected from excess moisture c Be solid level rigi...

Страница 8: ...ly to the pump Additionally if a suitable socket outlet is not available a weatherproof socket must be installed by an electrician in a suitable location RCD tripping indicates an electrical problem I...

Страница 9: ...metal piping in accordance with the wiring rules Run a wire from the equipotential bonding terminal on the pump bottom left motor bolt with serrated washer to the pool bonding structure Figure 1 Bondi...

Страница 10: ...cate the oring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes i...

Страница 11: ...e Speed Pump Installation and User s Guide If power is connected to the SuperFlo VS Variable Speed Pump motor pressing any of the following buttons referred to in this section could result in the moto...

Страница 12: ...must be pressed and the LED lit for the pump to run 7 OPERATING THE PUMP etting the Clock When the pump is first plugged in the clock will blink o indicate that is has not been set Any daily schedule...

Страница 13: ...ill run the custom user programmed schedule 2 00 Figure 5 Setting Duration 8 SUPERFLO VS Variable Speed Pump Installation and User s Guide Custom Schedules To customize the run schedule for your Super...

Страница 14: ...custom user programmed schedule Note If the pump has been stopped via the Start Stop button the pump will not run until the pump is turned back on by the Start Stop button If the Start Stop LED is ill...

Страница 15: ...ick Clean prior to the duration being completed you can press and hold the Quick Clean button for 3 seconds and the pump will return to the appropriate point in the programmed schedule If power is con...

Страница 16: ...le through the following things PrI Priming Speed PrI Remaining Time Once priming has begun the speed can be adjusted between 3450 and 1700 RPM using the and arrows If it is adjusted below 1700 RPM Pr...

Страница 17: ...the motor can still be stopped by pressing the Start Stop button However the motor can not be started again until the user unlocks the keypad Keypad Lockout Key lockout will not prevent the motor fro...

Страница 18: ...ns Also write down the Priming Speed 3 Press and hold the 1 2 3 and Quick Clean buttons for 3 seconds 4 The screen will display FACt rSt if factory reset is successful See Figure 13 5 Be sure to repro...

Страница 19: ...4 shows one of many potential wiring options available to the installer allowing you to install External Controls in the way that best suits your needs Note This 5V Signal red wire is output from the...

Страница 20: ...solved by this priority Quick Clean Speed 3 Speed 2 and then Speed 1 External Control Only Mode External Control Only mode will only allow the pump to run from external controls inputs When this mode...

Страница 21: ...leaves or debris which could become a fire hazard or choke the motor fan Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal Call a Pentai...

Страница 22: ...p from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer ve...

Страница 23: ...section of this manual Reset to default if necessary Motor high temperature limit exceeded Ensure motor fins are clean and fan is intact and free from blockages Ensure adequate ventilation and reduce...

Страница 24: ...mproper supply voltage Internal Errors These errors can occur based on operating conditions and the UL 60730 required self diagnostic safety software If they do not clear after multiple restart attemp...