background image

Operating the Pump White Running

Pressing the 

Display

 button will cycle through the current parameters.

 Speed

 — current run speed

 Time

 — current time of day

 Duration

 — amount of time remaining at the current run speed

• 

Watts

 — amount of watts currently being consumed

Pressing any of the Speed Buttons (“

1

”, “

2

”, “

3

”, “

Quick Clean

”) while the pump is running will act as 

temporary override. It will run the speed and duration that is programmed for that button. Once completed 

it will default back to the appropriate point in the programmed schedule.

Note:

 If you adjust the speeds of the schedule while the pump is running, it will run the adjusted speed 

for the rest of the current duration, but will not save the adjustments. 

Exception: Speed and Duration 

adjustments to QUICK CLEAN will always be immediately saved.

If running Quick Clean, pressing the “

+

” or “

-

” arrows will change the speed accordingly. Pressing the 

Quick Clean button again within 10 seconds of pressing the “

+

” or “

-

” arrows will allow you to adjust the 

duration of Quick Clean via the “

+

” and “

-

” arrows. These changes will be saved immediately and are the 

new defaults for Quick clean. Pressing the Quick Clean button again will cycle through the two Quick Clean 

settings. The pump will exit out of editing mode if no additional buttons are pressed within 10 seconds.

If Quick Clean is running and you wish to stop the Quick Clean prior to the duration being completed you 

can press and hold the Quick Clean button for 3 seconds and the pump will return to the appropriate point 

in the programmed schedule.

If power is connected to the pump motor, pressing any of the following 

buttons referred to in this section could result in the motor starting. Failure 

to recognize this could result in personal injury or damage to equipment.

Priming

This pump is shipped with Priming mode ENABLED. Unless the Priming 

settings are changed in the menu,

 be aware that the pump will speed up to 

the priming speed when the pump is powered on for the first time, and the

start/stop button is pressed.

Before turning the pump ON, be sure the following conditions are met:

1. Open filter air relief valve.

2. Open valves.

3. Pool return is completely open and clear of any blockages.

4. Water in the pump basket.

5. Stand clear of the filter or other pressurized vessels.

CAUTION

CAUTION

DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be 

damaged and the pump will start leaking. If this occurs, the damaged seal 

must be replaced. ALWAYS maintain proper water level in your pool (half way 

up skimmer opening). If the water level falls below the skimmer opening, 

the pump will draw air through the skimmer, losing the prime and causing 

the pump to run dry, resulting in a damaged seal. Continued operation in this 

manner could cause a loss of pressure, resulting in damage to the pump case, 

impeller and seal and may cause property and personal injury.

CAUTION

Quick Clean

14

Operation

Содержание Sta-rite EnviroMAX 1500

Страница 1: ...Variable Speed Pool Pump...

Страница 2: ...available When you see the Eco Select brand on one of our products you ll know it is our greenest and most efficient product in that equipment category These products do the best job of saving energy...

Страница 3: ...6 Pool Outlets 6 Electrical 7 Equipotential Bonding 7 Operation Priming the Pump 9 Control Panel Overview 10 Setting Clock 11 Using Default Schedule 11 Custom Schedules 12 Operating the Pump While Ru...

Страница 4: ...rotected motor prevents damage by automatically shutting down the motor in the event of a locked rotor under voltage over voltage or over current condition and will automatically reduce the speed duri...

Страница 5: ...ing IPX6 Inlet Suction ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Max Total Head 21m Max Working Pre...

Страница 6: ...0 2 4 6 8 10 12 14 16 18 20 22 Head m Flow L min 3 1 5 0 R P M 2850RPM 2600RPM 2400RPM 2200RPM 2000RPM 1800RPM 1600RPM 1400RPM 1200RPM 0 50 100 150 200 250 300 350 400 450 500 550 600 650 279mm 515mm...

Страница 7: ...ion 200sq cm min inlet outlet and air circulation Allow 200mm to keep rear of motor clear b Have adequate floor drainage to prevent flooding and be protected from excess moisture c Be solid level rigi...

Страница 8: ...ly to the pump Additionally if a suitable socket outlet is not available a weatherproof socket must be installed by an electrician in a suitable location RCD tripping indicates an electrical problem I...

Страница 9: ...metal piping in accordance with the wiring rules Run a wire from the equipotential bonding terminal on the pump bottom left motor bolt with serrated washer to the pool bonding structure Figure 1 Bondi...

Страница 10: ...cate the oring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes i...

Страница 11: ...e Speed Pump Installation and User s Guide If power is connected to the SuperFlo VS Variable Speed Pump motor pressing any of the following buttons referred to in this section could result in the moto...

Страница 12: ...must be pressed and the LED lit for the pump to run 7 OPERATING THE PUMP etting the Clock When the pump is first plugged in the clock will blink o indicate that is has not been set Any daily schedule...

Страница 13: ...ill run the custom user programmed schedule 2 00 Figure 5 Setting Duration 8 SUPERFLO VS Variable Speed Pump Installation and User s Guide Custom Schedules To customize the run schedule for your Super...

Страница 14: ...custom user programmed schedule Note If the pump has been stopped via the Start Stop button the pump will not run until the pump is turned back on by the Start Stop button If the Start Stop LED is ill...

Страница 15: ...ick Clean prior to the duration being completed you can press and hold the Quick Clean button for 3 seconds and the pump will return to the appropriate point in the programmed schedule If power is con...

Страница 16: ...le through the following things PrI Priming Speed PrI Remaining Time Once priming has begun the speed can be adjusted between 3450 and 1700 RPM using the and arrows If it is adjusted below 1700 RPM Pr...

Страница 17: ...the motor can still be stopped by pressing the Start Stop button However the motor can not be started again until the user unlocks the keypad Keypad Lockout Key lockout will not prevent the motor fro...

Страница 18: ...ns Also write down the Priming Speed 3 Press and hold the 1 2 3 and Quick Clean buttons for 3 seconds 4 The screen will display FACt rSt if factory reset is successful See Figure 13 5 Be sure to repro...

Страница 19: ...4 shows one of many potential wiring options available to the installer allowing you to install External Controls in the way that best suits your needs Note This 5V Signal red wire is output from the...

Страница 20: ...solved by this priority Quick Clean Speed 3 Speed 2 and then Speed 1 External Control Only Mode External Control Only mode will only allow the pump to run from external controls inputs When this mode...

Страница 21: ...leaves or debris which could become a fire hazard or choke the motor fan Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal Call a Pentai...

Страница 22: ...p from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer ve...

Страница 23: ...section of this manual Reset to default if necessary Motor high temperature limit exceeded Ensure motor fins are clean and fan is intact and free from blockages Ensure adequate ventilation and reduce...

Страница 24: ...mproper supply voltage Internal Errors These errors can occur based on operating conditions and the UL 60730 required self diagnostic safety software If they do not clear after multiple restart attemp...

Страница 25: ...24 Replacement Parts 4 3 5 11 12 1 10 2 13 15 16 14 8 7 6 9 9a 9b 9c 9d...

Страница 26: ...See Pump Fasteners Kit PUMP FASTENERS KIT 1 801280 9 PUMP CASING ASSEMBLY C176 71P 9a LID 1 17307 0111 9b O RING LID 1 35505 1440 9c BASKET 1 C8 58P 9d DRAIN PLUG O RING 2 U178 920P 10 O RING PUMP CA...

Страница 27: ...26 Notes...

Страница 28: ...664 266 Email au sales pentair com Web www pentairpool com au Information contained here in remains the property of Pentair Australia Pty Ltd Any reproduction display publication modification or dist...

Отзывы: