230 V
A2
A1
EARTH
NEUTRAL (N)
PHASE (L)
NEUTRAL (N)
DIRECTION 1
DIRECTION 2
230 V
230 V
12 V
< 1600 W
NEUTRAL (N)
PHASE (L)
OUT 1
OUT 2
COMM. SPEED 1 SPEED 2 SPEED 3 SPEED 4
BUS
IN 1
IN 2
OUT 3
N
L
230 V ~
OUT 1
OUT 2
COMM. SPEED 1 SPEED 2 SPEED 3 SPEED 4
BUS
IN 1
IN 2
OUT 3
N
L
230 V ~
Outlet: connection for a 3-way motorised valve (OTHER)
1 - Connect the cables in accordance with the diagram.
2 - Start the secured
Install menu
(from the main menu,
simultaneously hold down
Esc
and
Valid
for 3 secs. A star
appears in the top right corner of the home screen).
3 - On the
Outlets / S1-S2-S3
sub-menu (in accordance with
chosen terminal), select
OTHER
to indicate that a motorised
valve is connected to the corresponding outlet
.
1 - Connect the cables in accordance with the diagram.
2 - Start the secured
Install menu
(from the main menu, simultaneously hold down
Esc
and
Valid
for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the
Inlets / E1
sub-menu, select
LIGHTING
to indicate that a dry contact has been connected to the corresponding inlet
.
4 - For IntelliBrite and other LED lights with colours that may change with impulses,
on the Home menu, select
Lighting
and validate the chosen light programme type:
Outlet: connection for lighting below 1,600 W
-Mode : Californian
An outlet is a dry contact and does not
supply any voltage.
An outlet is a dry contact and does not supply any
voltage.