4
3
2
1
5 6 7 8 9 10 11
Terminal mode:
P12 = 0
P15 = 2
Common = 50
Speed 1 = 51
Speed 2 = 52
Speed 3 = 53
Speed 4 = 54
COMM. SPEED 1 SPEED 2 SPEED 3 SPEED 4
COMM. SPEED 1 SPEED 2 SPEED 3 SPEED 4
On the pump, control the speeds N1 < N2 < N3 < N4 and N4 at 100% / 'EXTERNAL = FIX SPEED'
and 'SIGNAL = CONTINUED'. - The pump functions for 5 minutes at maximum speed after starting.
SPECK 90 Eco Motion: Connections and functions
1 - Connect a 5 x 0.75 mm2 cable in accordance with the diagram.
2 - Start the secured Install menu (on the main menu, press Esc and Valid at the same time for 3 secs. A star
appears in the top right corner of the home screen).
3 - On the Filtration Speed / Type sub-menu, select 4 speeds and hold down Valid.
This assembly allows a standard filtration pump with a fixed speed to be transformed into a pump with
variable speeds, and also benefits from a strong energy gain.
Invertek Drives / Optidrive E2 variator: Connections
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (on the main menu, press Esc and Valid at the same time for 3 secs. A star
appears in the top right corner of the home screen).
3 - On the Filtration Speed / Type sub-menu, select Invertek and hold down Valid.