Installer manual Siata V132 - SFE - Troubleshooting
Ref. MKT-IM-003 / B - 19.04.2017
75 / 88
Leaks to the drain
during service or
when in stand-by.
Leak through the piston /seals and
spacer system.
If the water leaking from the drain is
softened check for damages on the
outlet part of the valve, in particular
outlet piston or seals and spacers.
Otherwise check for damages on the
inlet part of the valve.
Dismount the pistons and the seals
and spacer pack. Visually check every
items inside the valve and replace the
damaged part. If more that a third of
the total O-rings needs to be replaced,
change the complete piston and seals
and spacers sub-assembly.
Hard water
detected in the
outlet.
Probable leakage between inlet and
outlet or between the valve and tank
seal.
A
Damage on the inlet internals O-
ring (
1
) and (
2
) or on the inlet
piston. Dismount the valve and
visually check these items.
Replace them if they are damaged.
B
The rise pipe O-ring may be
damaged, disconnect the valve
from the tank and check the O-ring
status.
High pressure drop is causing the
opening of the automatic bypass.
If mixing is not desired replace the
automatic bypass with a manual
bypass model.
Inlet piston is out of position causing
bypass between inlet and outlet.
In that case a leakage on the drain
should also be observed. Check for
problems on the pilot circuit otherwise
check if the pilot pressure is in
compliance with the valve
specifications. For twin pilot valves,
the screen inside the manifold may be
plugged by dirt causing pressure drop
on the pilot circuit. Remove and clean
it.
Bypass valve not closed.
Ensure that the bypass valve is closed.
Issue
Cause
Reset and recovery
Содержание Siata V132 SFE
Страница 1: ...SIATA V132 SFE...
Страница 14: ...Installer manual Siata V132 SFE Description 14 88 Ref MKT IM 003 B 19 04 2017 3 3 Outline drawing...
Страница 15: ...Installer manual Siata V132 SFE Description Ref MKT IM 003 B 19 04 2017 15 88 PAGE INTENTIONALLY LEFT BLANK...
Страница 55: ...Installer manual Siata V132 SFE Commissioning Ref MKT IM 003 B 19 04 2017 55 88 PAGE INTENTIONALLY LEFT BLANK...
Страница 59: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 59 88...
Страница 61: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 61 88...
Страница 63: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 63 88...
Страница 65: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 65 88...
Страница 67: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 67 88...
Страница 69: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 69 88...
Страница 71: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 71 88...
Страница 73: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 73 88...
Страница 78: ...Installer manual Siata V132 SFE Spare parts 78 88 Ref MKT IM 003 B 19 04 2017 11 2 Valve parts list...
Страница 82: ...Installer manual Siata V132 SFE Spare parts 82 88 Ref MKT IM 003 B 19 04 2017 11 3 SFE spare parts...
Страница 88: ...www pentairaquaeurope com...