Installer manual Siata V132 - SFE - System sizing
Ref. MKT-IM-003 / B - 19.04.2017
29 / 88
4.2.5. Cycle time calculation
From this point, the volume of resin, the tank size and the capacity of the softener is determined. Next
step is to calculate the regeneration cycle time, which depends on the valve configuration and once
again on the resin specifications.
Note
Preprogrammed cycle times are only factory default programming that need to be adjusted
to fit the system requirements).
For cycle time calculation the valve configuration must be known, which depends on:
•
the tank size;
•
the resin volume previously determined;
•
the salt amount desired per regeneration;
•
the resin specifications for the volume of water to use for backwashing the resin bed;
•
the velocity and volume of water for brine draw and slow rinse;
•
the volume of water to use for fast rinse.
To calculate the backwash duration:
T
backwash
= (V
resin
x N
BV
) / Q
backwash
Note
The typical value of the volume of water to be used for backwash is between 1.5 and 4 times
the bed volume, depending on the inlet water quality.
To calculate the brine draw duration:
Knowing the injector flow rate at the working pressure:
T
brine draw
= V
brine
/ Q
inj
Note
Multiply the amount of salt in kg by 3 to get a correct approximation of the brine volume to
draw.
A
with:
T
backwash
: backwash duration [min]
V
resin
: volume of resin [L]
N
BV
: number of bed volume needed for backwash
Q
backwash
: backwash flow rate which is controlled by the
DLFC [L/min]
A
with:
T
brine draw
: brine draw duration [min]
V
brine
: brine volume to be drawn [L]
Q
inj
: injection flow rate [L/min]
A
Содержание Siata V132 SFE
Страница 1: ...SIATA V132 SFE...
Страница 14: ...Installer manual Siata V132 SFE Description 14 88 Ref MKT IM 003 B 19 04 2017 3 3 Outline drawing...
Страница 15: ...Installer manual Siata V132 SFE Description Ref MKT IM 003 B 19 04 2017 15 88 PAGE INTENTIONALLY LEFT BLANK...
Страница 55: ...Installer manual Siata V132 SFE Commissioning Ref MKT IM 003 B 19 04 2017 55 88 PAGE INTENTIONALLY LEFT BLANK...
Страница 59: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 59 88...
Страница 61: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 61 88...
Страница 63: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 63 88...
Страница 65: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 65 88...
Страница 67: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 67 88...
Страница 69: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 69 88...
Страница 71: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 71 88...
Страница 73: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 73 88...
Страница 78: ...Installer manual Siata V132 SFE Spare parts 78 88 Ref MKT IM 003 B 19 04 2017 11 2 Valve parts list...
Страница 82: ...Installer manual Siata V132 SFE Spare parts 82 88 Ref MKT IM 003 B 19 04 2017 11 3 SFE spare parts...
Страница 88: ...www pentairaquaeurope com...