background image

General Safety Information   

2

Description

Myers Drainer Pre-Plumbed System, Model Number 

ED33V1, is ideal for home wastewater removal from 

beautician or utility sinks and wet bars, and for drain 

water transfer from air conditioners or dehumidifiers.  

1/3 HP submersible pump unit is equipped with a 3-prong 

grounding-type power cord. Motor is oil-filled (dielectric 

oil) and sealed for cooler running. Upper sleeve/lower 

ballbearing on motor shaft never need lubrication. 

Automatic reset thermal protection.

specifications

Power supply required ..................................115V, 60 Hz.
Liquid temp. range ......................................... 32° to 130°F
Individual branch circuit required (minimum) ..... 15 Amps
Discharge .......................................................... 1-1⁄2" NPT

Unpacking anD inspection

Handle with care. Check items received against packing 

list to be sure that all equipment has been received. 

Inspect for shipping damage. If found, file claim with 

carrier immediately.

general safety information

Electrically powered sump pumps normally give many 

years of trouble-free service when correctly installed, 

maintained, and used. However, unusual circumstances 

(interruption of power to the pump, dirt/debris in the 

sump, flooding that exceeds the pump’s capacity, 

electrical or mechanical failure in the pump, etc.) may 

prevent the pump from functioning normally. To prevent 

possible water damage due to flooding, consult your 

dealer about installing a high water alarm. See the 

“Troubleshooting Chart” in this manual for information 

about common sump pump problems and remedies. 

For more information, see your dealer or call customer 

service.
1.  Know the pump application, limitations, and potential 

hazards.

2.  Disconnect power before servicing.
3.  Release all pressure within system before servicing any 

component.

4.  Drain all water from system before servicing.

5.  Secure discharge line before starting pump. An 

unsecured discharge line will whip, possibly causing 

personal injury and/or property damage.

6.  Check hoses for weak or worn condition before each 

use, making certain that all connections are secure.

7.  Periodically inspect system components. Keep 

free of debris and foreign objects. Perform routine 

maintenance as required. 
8.  Provide means of pressure relief for pumps whose 

discharge line can be shut-off or obstructed.

9.  Personal Safety:

a.  Wear safety glasses at all times when working with 

pumps.

b.  Keep work area clean, uncluttered and properly 

lighted – replace all unused tools and equipment.

c.  Keep visitors at a safe distance from work area.
d.  Make workshop child-proof – with padlocks, 

master switches, and by removing starter keys.

10. When wiring an electrically driven pump, follow all 

electrical and safety codes that apply.

11. This equipment is only for use on 115 volt (single 

phase) and is equipped with an approved  

3-conductor cord and 3-prong, grounding-type plug.

to reduce risk of electric shock, pull plug 

before servicing.

 This pump has not been investigated 

for use in swimming pool areas. Pump is supplied with 

a grounding conductor and grounding-type attachment 

plug. Be sure it is connected only to a properly grounded 

grounding-type receptacle. Where a 2-prong wall 

receptacle is encountered, it must be replaced with 

a properly grounded 3-prong receptacle installed in 

accordance with codes and ordinances that apply.
12. All wiring should be performed by a qualified  

electrician.

13. Make certain power source conforms to requirements 

of your equipment.

14. Protect electrical cord from sharp objects, hot surfaces, 

oil, and chemicals. Avoid kinking cord. Replace or 

repair damaged or worn cords immediately.

15. Do not touch an operating motor. Modern motors are 

designed to operate at high temperatures.

performance

specifications

 

gpm of Water @ total feet of Head 

  

model 

Hp 

5’ 

10’ 

15’ 

20’ 

shutoff

 

eD33V1

 1/3  48.0 40.0  29.0 15.0  24’

 

 

 motor  

 

 

 

 

full load 

switch setting 

 

top 

Bottom 

  

Hp 

amps 

on 

off 

Height 

Width 

Width 

Weight

 

1/3 

9.8 

7" 

2" 

13-3/4" 

15-1/8" 

12" 

32 lbs.

Содержание Myers ED33V1

Страница 1: ...Pentair Ltd All Rights Reserved MY483 Rev 03 21 13 293 WRIGHT STREET DELAVAN WI 53115 WWW FEMYERS COM PH 888 987 8677 ED33V1 Installation Operation Parts For further operating installation or mainten...

Страница 2: ...hip possibly causing personal injury and or property damage 6 Check hoses for weak or worn condition before each use making certain that all connections are secure 7 Periodically inspect system compon...

Страница 3: ...d switch from the electrical power source before doing any maintenance 16 Pump water only with this pump California Proposition 65 Warning This product and related accessories contain chemicals known...

Страница 4: ...tep 7 IMPORTANT To prevent leaks be sure the locating cleats on the corners of the basin gasket are outside the edges of the basin rim not pressing against the rim Installation See Figure 7 The basin...

Страница 5: ...complete cycle Risk of flooding Failure to make this operational check may lead to improper operation premature failure and flooding Maintenance Risk of electric shock Make certain that the pump is u...

Страница 6: ...entire cycle without interference from sidewall of basin plumbing or any other object 1 Mount bracket on switch housing using existing screws 2 Slide rod into slot in bottom of switch housing Fasten r...

Страница 7: ...ly includes Key No 2 and hardware kit 1 PW73 64 2 Basin Gasket 1 U20 23 3 Automatic Vertical Float Switch 1 PKG 208 4 1 1 2 Discharge Pipe 1 U37 688P 5 1 3 HP Submersible sump pump 1 D33110V Hardware...

Страница 8: ...YERS repair or replace defective products at F E MYERS s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing deale...

Страница 9: ...es 2013 Pentair Ltd All Rights Reserved MY483 R v 21 03 13 293 WRIGHT STREET DELAVAN WI 53115 WWW FEMYERS COM PH 888 987 8677 Installation Fonctionnement Pi ces Pour plus de renseignements concernant...

Страница 10: ...es blessures corporelles et ou des dommages mat riels 6 Avant chaque utilisation s assurer que les tuyaux souples ne sont pas us s ni affaiblis et que tous les raccords sont bien serr s 7 P riodiqueme...

Страница 11: ...proc der un entretien 16 Ne pomper que de l eau avec cette pompe Avertissement li la Proposition 65 de la Californie Ce produit et les accessoires connexes contiennent des produits chimiques reconnus...

Страница 12: ...ls n appuient pas contre le rebord Installation Voir la Figure 7 Le bassin du syst me doit tre positionn de fa on qu il soit le plus bas possible par rapport la zone vider REMARQUE S assurer que l arr...

Страница 13: ...ent en faisant le plein d eau de la pompe et en observant le fonctionnement de la pompe pendant un cycle complet Risque d inondation Ne pas proc der cette v rification de fonctionnement peut causer un...

Страница 14: ...les parois du bassin les tuyaux ou tout autre objet 1 Monter le support sur le bo tier de l interrupteur l aide des vis existantes 2 Glisser la tige dans la fente qui se trouve la partie inf rieure d...

Страница 15: ...64 2 Panier de collecteur 1 U20 23 3 Interrupteur flotteur vertical fonctionnement automatique 1 PKG 208 4 Tuyau de refoulement de 1 1 2 pouce 1 U37 688P 5 Pompe submersible de puisard de 1 3 de ch 1...

Страница 16: ...consistent r parer ou remplacer au choix de F E MYERS les produits qui se r v leraient d fectueux L Acheteur s engage payer tous les frais de main d uvre et d exp dition du produit couvert par sa gara...

Страница 17: ...13 Pentair Ltd All Rights Reserved MY483 Rev 03 21 13 293 WRIGHT STREET DELAVAN WI 53115 WWW FEMYERS COM PH 888 987 8677 ED33V1 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamie...

Страница 18: ...e descarga antes de poner en marcha la bomba Una l nea de descarga no asegurada debidamente podr dar un golpe y causando posiblemente lesiones personales y o da os a la propiedad 6 Verifique que las m...

Страница 19: ...mba y el interruptor de la fuente de suministro de corriente el ctrica antes de realizar alg n trabajo de mantenimiento 16 Solamente bombee agua con esta bomba Advertencia de la Proposici n 65 de Cali...

Страница 20: ...orde de la pileta no oprimidas contra el reborde Instalaci n Ver Figure 7 La pileta el sistema debe estar ubicado en el lugar m s bajo posible con respecto a la zona que se debe drenar NOTA Verifique...

Страница 21: ...l funcionamiento de la bomba a trav s de un ciclo completo Riesgo de inundaci n Si no se realiza este chequeo operacional existe el riesgo de un funcionamiento inadecuado fallas prematuras e inundaci...

Страница 22: ...a pileta de los componentes de plomer a ni de ning n otro objeto 1 Coloque el soporte en la caja del interruptor usando los tornillos existentes 2 Deslice la vara en la ranura del fondo de la caja del...

Страница 23: ...rios de ferreter a 1 PW73 64 2 Empaquetadura de la pileta 1 U20 23 3 Interruptor autom tico de flotador vertical 1 PKG 208 4 Tubo de descarga de 1 1 2 1 U37 688P 5 Bomba sumergible de sumidero de 1 3...

Страница 24: ...YERS es que F E MYERS repare o reemplace los productos defectuosos a juicio de F E MYERS Usted deber pagar todos los cargos de mano de obra y de env o asociados con esta garant a y deber solicitar el...

Отзывы: