EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
35
IntelliFlo VS and VSF+SVRS Settings
Selecting the IntelliFlo PUMP TYPE
To access the IntelliFlo menu:
MENU
s
SETTINGS
s
INTELLIFLO
w
PUMP#1
Up/Down button:
Choose
Pump #1
.
Right button:
Select
Pump #1
.
Right button:
Select
Pump Type
. Note: To change the current pump type for Pump
#1. press the
Up/Down
button and select
Y
, then press the
Right button
. To continue
to the Pump #1 settings menu, press the
Right button
(or
Menu
to exit).
Settings Menu: IntelliFlo
®
Pump
(Continued)
Connecting Power to the IntelliFlo Pump
The IntelliFlo pump is designed to be permanently connected to its power source. Typically the pump receives
power directly from the circuit breaker. No contactor or motor starter is required. The drive controls the
starting and stopping of the pump. If the IntelliFlo pump is connected to an automation system, such as the
EasyTouch PL4/PSL4 Control System, the drive must be powered up to receive and respond to the RS-485
serial communication from the automation system. However, the pump can be operated in “stand-alone”
mode, starting and stopping when power is applied or removed. When the drive powers up it will return to
the mode and run status that it was in when power was removed. This setup is appropriate if you need to use
existing relays or timers.
Assigning an IntelliFlo VS 3050 pump address
Before assigning a pump address at the EasyTouch PL4/PSL4 Control
System indoor, wireless or outdoor control panel, first set the address
on
the pump itself.
The pump's default address is pump #1.
To assign an IntelliFlo VS 3050 pump address:
1. Be sure that the pump is powered on and the green power LED
is on.
2. Press the
Stop
buttons to stop the pump.
3. Press and hold both the
Start and Stop
buttons until the red
LED will starts flashing, then press one of the four speed
buttons (1-4) to select which address to assign the pump. For
example, if you are assigning the pump as pump #1, then press
Speed button number 1.
4. Press and hold both the
Start and Stop
buttons to save the
address. Repeat the process for the other pumps.
NOTE: INTELLIFLO IN “SERVICE MODE” - IntelliFlo pumps will STOP when the system is in ‘Service” mode.
NOTE: INTELLIFLO “FREEZE” PROTECTION - If the IntelliFlo pump is on due to a freeze condition (not switch
on from a relay circuit), and if a freeze protect for a certain speed is set, this setting takes priority even if the
previous setting is lower than the default circuit speed. If no “freeze” protection is set, the pump will be forced on
at the default circuit speed. Any programmed or manual operation that actually switches on a circuit, will cause the
pump to run at that speed if it is higher.
SELECT PUMP TYPE: Up/Down buttons:
Choose
VS
or
VSF+SVRS
.
Menu button:
Press the
MENU
button to save selection and return to the selected
pump’s menu settings (see VS and VSF pump settings descriptions below)
Pump #1
Changing Pump1’s
Type will config
it to default.
Continue ? N
Pump Type
Speeds
Priming
Status
IntelliFlo VS Pump Speed buttons (1-4)
Speed
1
Speed
2
Speed
3
Speed
4