![Pentair EASYTOUCH PL4 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/pentair/easytouch-pl4/easytouch-pl4_user-manual_1524370023.webp)
EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
15
Quick Start - (Pool and Spa Operations (Shared Equipment)
Continued
Heat your spa or pool
First enable the heat source (see “Adjust your spa heat settings” below) then press the
Valves (V)
button to enable “Spa” mode, and press the
Filter Pump
button to activate
the filter pump. When in normal operating mode, the Valves (V) button is in “Pool” mode
which turns valves and activates the filter pump automatically so that only the pool water
is circulated through the system. Press the button to enable “Spa” mode and activate the
Filter pump to circulate only spa water through the system. In the main screen shown on
left, 95°F (35°) is the current temperature and 100° F
(38° C) is set point temperature. By default, the setting “
Man Heat’
is set to “
On
” (see
page 53) which allows the spa to begin to heat whenever it is manually switched on.
From the Indoor or wireless control panel (option):
First enable the heat source in the
Heat menu (see “Heat Menu,” on page 30). Press the
Spa
button (top button) to switch
the filter pump on, rotate the valve actuator (to isolate spa water from pool water), and
switch the heater on. Press the
Pool
button to switch the filter pump on, rotate the valve
actuator (to isolate pool water from spa water), and switch the heater on. For Pool and
Spa button location, see page 5 (#6).
Adjust your spa or pool heat settings
From the “Heat” menu (
MENU > HEAT > POOL TEMP/SRC OR SPA TEMP/SCR
) you can select the heat source
and set the water temperature. The spa or pool water will heat to the settings specified. The EasyTouch PL4/PSL4
Control System allows for solar and conventional heaters. The system will use the heating source that is selected.
The heat source selections are:
•
OFF -
No heating even though pump and other circuits may be operating.
•
HEATER -
Gas heater only.
•
SOLAR
- Solar heating system to be the only heat source. In order to display “Solar Only” as a heat
option in the “Heat” menu, you must first enable solar in the
Settings > Solar
menu,
(see page 49).
•
SOLAR PREF.
(Solar Preferred)
- Used if solar and gas heating are combined and you want to use
solar heating only when it is most effective. In order to display “Solar Preferred” as a heat option in the
“Heat” menu, you must first enable solar in the
Settings > Solar
menu.
•
Heat Pump (UltraTemp):
If a heat pump is being used (UltraTemp), enable the UltraTemp and heating
setting from the
SETTINGS > HEAT PUMP COM > SETTINGS
menu options (see page 41).
To set the spa temperature set point and select the heat source:
MENU
s
HEAT
Right button:
Select spa temperature and heat source.
Up/Down button:
Adjust the spa water temperature from 40° F to 104° F
(4° C to 40° C)
Right or Left button:
Move to Heat source options.
Up/Down:
Set the Heat option:
Off, Heater, Solar,
or
Solar Preferred
.
Press the
Menu
button to save the settings and to return to the Heat menu or press the
button again to return to the main screen.
Note:
Select “
POOL Temp/Src
” to adjust the
pool temperature.
AUTO HEATER
SPA 85°F / 100°F
AIR 70°F
MON 09:30 AM
POOL Temp/Src
SPA Temp/Src
SPA
Set Temp: 85° F
Heat: Heater
The following describes how to adjust heat temperature for the spa and pool water, schedule a daily run time for
the pool/spa filter pump and control lights for shared equipment.