9. Installing the Cartridges

 

The cartridges are identified by the color of the label and 
the model number.

 

Cartridge #1 = PW-S2500R, Yellow 

Cartridge #2 = PW-C5000R, Blue 

Cartridge #3 = PW-RO75R, Green 

Cartridge #4 = PW-C2500R, Violet

 

Install the cartridges in order. If the cartridges are installed 
out of order the system will not filter correctly.

 

A.  Slide the cartridge into the head until it stops.

 

B.  Twist the cartridge 1/4 turn clockwise until it snaps into 

place. Gently pull out on the cartridge to ensure the 
cartridge is locked into place.

 

11. Putting the System Into Operation

 

CAUTION 

Make certain head assembly is firmly attached 

to wall to prevent it from falling and possibly 
becoming damaged.

 

NOTE: Use caution not to bend or pinch the tubing behind 

the system while attaching to mounting screws.

 

NOTE: The post-polishing filter may contain fine black 

carbon particles. These fines are harmless, but 
may make the water appear gray in color. The 
carbon fines are flushed from the system with the 
first tank full of water.

 

NOTE: The PB4RO system does not produce a high 

volume of water on demand as an ordinary filter 
does. Water is produced at a slow, drop-by-drop 
rate. The system requires about 3 hours to fill the 
storage tank. As water is taken from the tank, the 
system automatically starts the cycle of replacing 
the water and then stops water production when 
the tank is full.

 

 

2

 

Qui ck Ch ang e 

Sed im ent 

Cartridg e

 

 

 

CA PAC IT Y :

 

Repl ace  ever y 12  mont hs

 

T E M P ER AT UR E  RA N G E:

 

40-1 00° F  (4. 4-37. 8°C )

 

PR E S S UR E  RAN G E :

 

30 -12 5° F ( 2. 4- 8.6  B a r)

 

For u se with 

P entair W ater 

m odels: P B 4RO-

75, PP 4RO-75 and 

P B 5RO-75

 

5

 

Qui ck 

Chang e 

EP 

Cartridg e

 

 

 

CA P A CI T Y :

 

Re plac e  

ev er y   1 2  

m on th s 

T E M P E R A T U

R E  R AN G E : 

40 -1 00° F  

(4 .4 -3 7.8 °C )

 

PR E S S UR E   
RAN G E :

 

30 -1 25  

°

F (2. 4-8.6  Bar)

 

For  u se  with 
P entair  Wat er  
m odels: P B 4RO -
75, P P 4RO-75 and 
P B 5RO-75

 

 

1

 

 

 

2

 

 

3

 

 

 

 

 

 

 

Figure 13

 

A.  Make sure cold water faucet is “off” (Figure 14).

 

B.  Make sure tank valve is in the open position.

 

C.  Slowly turn on cold water supply.

 

D.  Open the faucet to turn on flow. Let the faucet run/drip 

for 12 hours, then close it.

 

E.  Allow 3 hours for the tank to fill. Continue to periodically 

A

 

check the installation for leaks. After the storage tank

 

is filled, open the faucet to flush the post-filter cartridge 
(on the right side of the filter housing). Allow 4 to 5 
minutes for all of the water to drain from the tank. Close 
faucet and allow tank to fill.

 

CAUTION 

Visually check the entire system for leaks. If a leak is

 

10. Connecting the Storage Tank to the System

 

CAUTION  

When  tank  is  full,  it  weighs  approximately  35 

pounds.   Provide   ample   support   under   the   tank.

 

A.  Apply 3-5 wraps of Teflon tape to the tank threads.

 

B.  Thread the tank valve onto the top of the tank opening 

by turning it clockwise until snug.

 

C.  Locate the green tubing and a mark 3/4" from the end.

 

Moisten one end of the green tubing with water and 
insert with a twisting motion into the free port of the tank 
valve until the 3/4" mark is flush with the quick-connect 
fitting.

 

NOTE: Do not cut green tube. This line should be left at 

the pre-cut length for future service.

 

NOTE: The pressurized storage tank has capacity of

 

3.2 gallons. The tank's air pressure is factory 
set at 5 to 7 psi when tank is empty.

 

present, see TROUBLESHOOTING.

 

F.   Repeat Step E four times.

 

NOTE: Initially, the water may appear cloudy. This is a 

result of air trapped in the post-filter cartridge. 
It is not harmful and will disappear in a matter 
of minutes. It may take up to a week after 
installing a new post-filter cartridge for the 
trapped air to dissipate.

 

The system is ready for operation. You can now enjoy quality 
water from the PB4RO-75.

 

 

 

Closed 

Tank Valve

 

 

 

Open 

Tank Valve

 

 

 

 

 

 

 

Figure 14

 

Model PB4RO-75 Undersink Reverse Osmosis System JA12  • 9

 

 

Содержание PB4RO-75

Страница 1: ...or future reference Tools Required for plastic tubing Optional Materials hillips Screwdrivers rill Bits 1 8 1 4 and 3 8 owel afety Glasses ape Measure For sinks without extra hole for faucet enter punch espirator 3 8 Bi metal or Carbide Tipped Hole saw NOTE All tools listed will not be necessary for installation Read installation procedures before starting to determine required tools Parts Include...

Страница 2: ... than 2 to 3 days without being used the storage tank should be emptied NOTE Use only Teflon tape without adhesive backing to seal joints Do not use pipe compound pipe dope sticks or similar compounds with this unit they contain petroleum derivatives which can cause crazing and cracking of the plastic in the filter housing NOTE Use only soap and water to clean components NOTE Do not use aerosol sp...

Страница 3: ...d to allow faucet base to rest securely The faucet fits through a 1 3 8 hole Most sinks have pre drilled 1 3 8 or 1 1 2 diameter holes that may be used for faucet installation If these pre drilled holes cannot be used or are in an inconvenient location it will be necessary to drill a 1 3 8 hole in the sink to accommodate the faucet WARNING This proceduremaygeneratedust which can cause severe irrit...

Страница 4: ...is tube should be long enough to reach the drain clamp in Step 7 Will Spring Open C Notch For Faucet Figure 4 45 Notch For Faucet Blades Must Be Held When Tightening E Locate the 1 4 red brine tube from the right side of the system head assembly Route the tube through the faucet base and connect to small barb on the faucet Make certain that the tube is not kinked or stressed once the head assembly...

Страница 5: ...INSTALLATION continued Figure 3 Model PB4RO 75 Undersink Reverse Osmosis System JA12 5 ...

Страница 6: ...e PB4RO 75 two screws are supplied to mount the head Measure up from the floor of the cabinet 14 1 2 This will provide clearance to change the cartridges The two screws will be 14 apart and level Screw the two screws into the wall Leave a gap between the screw head and the wall of 1 8 The backside of the system head has two slots that will fit over the screw heads and slide down to lock 14 Inches ...

Страница 7: ...t fitting B Gently pull back on the tubing to ensure it is connected properly If the tubing comes out of fitting cut a small section off of the tubing and reconnect NOTE Tubing may be quickly and easily removed from the fitting if necessary First turn off the water supply to the filter Open faucet then press in the collet around the fitting while pulling the tubing with your other hand Step 8 A 3 ...

Страница 8: ...amp from the drainpipe and enlarge the hole with a 3 8 drill bit Use a file to remove rough edges from the drilled hole D Make sure the black rubber gasket is adhered to the inside of the drain clamp and place the drain clamp assembly over the drilled hole Look through the hole and position the clamp so that the center of the clamp hole is slightly higher about 1 16 than the center of the drilled ...

Страница 9: ...e place every 1 2 mon th s T EMPER A T U R E R AN G E 40 1 00 F 4 4 3 7 8 C PR ESSUR E RAN G E 30 1 25 F 2 4 8 6 Bar For u se with Pentair Wat er models PB4RO 75 PP4RO 75 and PB5RO 75 1 2 3 Figure 13 A Make sure cold water faucet is off Figure 14 B Make sure tank valve is in the open position C Slowly turn on cold water supply D Open the faucet to turn on flow Let the faucet run drip for 12 hours ...

Страница 10: ......

Страница 11: ...nk valve on top of storage tank C Turn off water to the system at the cold water supply D Open drinking water faucet to relieve pressure E Locate blue tubing leading to your drinking water faucet Cut and insert the 3 8 x 3 8 x 3 8 9 5 x 9 5 x 9 5 mm compression or quick connect tee into the blue tubing Figure 15 Consult manufacturer s guidelines before installing the tee connection NOTE When cutti...

Страница 12: ...dge on the left side of the filter housing counter clockwise for a 1 4 of a turn and pull the cartridge out of the system If the system has any significant leaks see Troubleshooting C Push the new cartridge into the head until it can go no further D Twist the cartridge 1 4 turn clockwise until it snaps into place E Gently pull the cartridge straight out to ensure the cartridge is locked into place...

Страница 13: ...F Repeat Step E four times Model PB4RO 75 Undersink Reverse Osmosis System JA12 ...

Страница 14: ......

Страница 15: ...tting 8 Turn water supply on at the saddle valve and close drinking water faucet 9 Allow system to pressurize for several hours and check for leaks 10 Check for leaks after tank is fully pressurized 1 3 hours If leak persists call Technical Support Leaks at Quick Connect Fittings CAUTION The 1 4 red tubing connected to the top of the fourth cartridge has a flow restrictor installed The system will...

Страница 16: ...ing water faucet 5 Using an air pressure gauge adjust the pressure in the storage tank to 5 7 psi 6 Replace the blue cap 7 Open the saddle valve until it comes to a stop Let the system run 1 3 hours to fill the tank A full tank weighs approximately 33 pounds If performance has not improved call Technical Support Sudden Return of Taste and Odor If shortly after complete servicing noticeable taste a...

Страница 17: ...G Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts NOTE Substances that may be reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement ...

Страница 18: ...10 11 14 JA12 Model PB4RO 75 Undersink Reverse Osmosis System ...

Страница 19: ...rom water very well RO systems are very effective at removing pentavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine may not convert all the trivalent arsenic If you...

Страница 20: ......

Страница 21: ...ng is 27 40 Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed PB4RO 75 Production Rate 24 83 gpd The PB4RO 75 is Tested and Certified by NSF International against NSF ANSI Standard 42 and 58 for the red...

Страница 22: ...ltration LLC prior to the expiration of the warranty date at the customer s expense shipment pre paid 4 be accompanied by a letter detailing the Model Number Serial Number if any and a brief description of the problem TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW PENTAIR RESIDENTIAL FILTRATION LLC DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIE...

Отзывы: