Substance
Influent Challenge
Concentration
Maximum
Permissible
Product Water
Concentration
Reduction
Requirements
Average
Reduction
Standard 58
Arsenic V
0.050 mg/L ± 10%
0.010 mg/L
97.6%
Barium
10.0 mg/L ± 10%
2.0 mg/L
96.7%
Cadmium
0.03 mg/L ± 10%
0.005 mg/L
98.2%
Chromium III
0.3 mg/L ± 10%
0.1 mg/L
97.6%
Chromium VI
0.3 mg/L ± 10%
0.1 mg/L
97.0%
Copper
3.0 mg/L ± 10%
1.3 mg/L
98.8%
Cysts
Minimum 50,000/mL
99.95%
99.99%
Fluoride
8.0 mg/L ± 10%
1.5 mg/L
96.2%
Lead
0.15 mg/L ± 10%
0.010 mg/L
99.0%
Radium
226/228
27pCi/L ± 10%
5pCi/L
80%
Selenium
0.10 mg/L ± 10%
0.05 mg/L
98.0%
Total Dissolved
Solids
750 mg/L ± 40 mg/L
187 mg/L
94.9%
Turbidity
11 mg/L ± 1 NTU
0.5 NTU
99.1%
Standard 42
Chlorine
2 mg/L
>=50%
93.0%
Performance Data
Important Notice: Read this performance data and compare
the capabilities of this system with your actual water treatment
needs. It is recommended that before installing a water
treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 58 for the
reduction of the substances listed below. The concentration
for the indicated substances in water entering the system
was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in
NSF/ANSI 58.
NOTE: Substances that may be reduced are not
necessarily in your water. Filter must be maintained
according to manufacturer’s instructions, including
replacement of filter cartridges.
The tested efficiency rating for this system is 15.80%.
Efficiency rating means the percentage of the influent water
to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage. The tested recovery rating is 27.40%.
Recovery rating means the percentage of the influent water
to the membrane portion of the system that is available to the
user as reverse osmosis treated water when the system is
operated without a storage tank or when the storage tank is
bypassed.
PB4RO-75
Production Rate: 24.83 gpd
The PB4RO-75 is Tested and Certified by NSF International
against NSF/ANSI Standard 42 and 58 for the reduction of
substances listed in the table above.
Testing was performed under standard laboratory conditions,
actual performance may vary.
Sta te o f Ca lifo rn ia
Department of Public Health
Water Treatment Device
Certificate Number
11 - 2097
Date Issued: October 24, 2011
Trademark/Model Designation
Replacement Elements
Pentair Water PB4RO-75
PW-RO75R
(RO Membrane)
PW-S2500R
(Pre Filters)
PW-C5000R
(Pre Filters)
PW-C2500R
(Post Filter)
Manufacturer:
Pentair Residential Filtration, LLC
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Cysts
Turbidity
Organic Contaminants
None
Arsenic (pentavalent)
1
Barium
Cadmium
Chromium (hexalent)
Chromium (trivalent)
Copper
Fluoride
Lead
Radium 226/228
Selenium
Rated Service Capacity:
1250 gal service cycle
Rated Service Flow:
24.8 gpd
Conditions of Certification:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified
for cyst reduction may be used on disinfected waters that may contain filterable cysts.
1
Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at the
reverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1 minute
chlorine contact time before the RO system.
Model PB4RO-75 Undersink Reverse Osmosis System JA12 • 15
Содержание PB4RO-75
Страница 5: ...INSTALLATION continued Figure 3 Model PB4RO 75 Undersink Reverse Osmosis System JA12 5 ...
Страница 10: ......
Страница 13: ...F Repeat Step E four times Model PB4RO 75 Undersink Reverse Osmosis System JA12 ...
Страница 14: ......
Страница 18: ...10 11 14 JA12 Model PB4RO 75 Undersink Reverse Osmosis System ...
Страница 20: ......