background image

1

 

D

 

INSTALLATION  

 

NOTE: Please read all instructions, specifications, and 

precautions before installing and using your 
PB4RO system.

 

NOTE: The PB4RO may be installed under a sink or in the 

basement.

 

NOTE: The PB4RO is installed vertically.

 

NOTE: Numbered diagrams correspond with numbered 

steps.

 

NOTE: For standard installation on 1/2" 14 NPS threads 

(most common thread on kitchen faucets) cold 
water line.

 

 

1. Installing the Water Supply Adapter

 

The supply adapter fits 1/2" 14 NPS supply threads. If local 
codes permit, it may be used to connect the filter system

 

to the cold water supply line. If local codes do not permit 
the use of the supply adapter, alternate connectors can be 
obtained from your local retailer.

 

A.  Turn off cold water supply line. If cold water line does 

not have a shut-off valve under the sink, one should be 
installed.

 

B.  Turn on the cold water faucet and allow all water to 

drain from line.

 

C.  Disconnect cold water line from 1/2" 14 NPS 

threaded stub on bottom of main faucet.

 

D.  Screw the water supply adapter to the threaded faucet 

stub as shown.

 

E.  Using the nut that previously connected the cold water 

line to the faucet, screw the cold water line to the male 
supply adapter threads.

 

 

 

2. Selecting the Faucet Location

 

NOTE: The drinking water faucet should be positioned 

with function, convenience, and appearance in 
mind. An adequate flat area is required to allow

 

faucet base to rest securely. The faucet fits through 
a 1-3/8" hole. Most sinks have pre-drilled 1-3/8" or

 

1-

1⁄2" diameter holes that may be used for faucet 

installation. If these pre-drilled holes cannot be 
used or are in an inconvenient location, it will

 

be necessary to drill a 1-3/8" hole in the sink to 
accommodate the faucet.

 

WARNING: 

This procedure may generate dust which  

can cause severe irritation if inhaled or come 
in contact with the eyes. The use of safety 
glasses and respirator for this procedure is 
recommended.

 

WARNING: 

Do not attempt to drill through an all- 

porcelain sink. If you have an all-porcelain 
sink, mount the faucet in pre-drilled sprayer 
hole or drill through countertop next to sink.

 

WARNING: 

When drilling through a countertop, make 

sure the area below the drilled area is free 
of wiring and piping. Make certain that 
you have ample room to make the proper 
connections to the bottom of the faucet.

 

WARNING: 

Do not drill through a countertop that is

 

more than 1" thick.

 

WARNING: 

Do not attempt to drill through a tiled, 

marble, granite or similar countertop. 
Consult a plumber or the countertop 
manufacturer for advice or assistance.

 

A.  Line bottom of sink with newspaper to prevent 

metal shavings, parts, or tools from falling down 
drain.

 

B.   Place masking tape over the area to be drilled to help 

prevent scratches if drill bit slips.

 

 

pilot hole.

 

D.   Using a 1-3/8" hole saw, drill a hole completely through 

the sink. Smooth the rough edges with a file.

 

 

F

 

 

A

 

 

 

Figure 1

 

 

 

C

 

C

 

4” 

B

 

 

1

1

4”

 

 

 

 

A

 

 

Figure 2

 

Model PB4RO-75 Undersink Reverse Osmosis System JA12  • 3

 

 

Содержание PB4RO-75

Страница 1: ...or future reference Tools Required for plastic tubing Optional Materials hillips Screwdrivers rill Bits 1 8 1 4 and 3 8 owel afety Glasses ape Measure For sinks without extra hole for faucet enter punch espirator 3 8 Bi metal or Carbide Tipped Hole saw NOTE All tools listed will not be necessary for installation Read installation procedures before starting to determine required tools Parts Include...

Страница 2: ... than 2 to 3 days without being used the storage tank should be emptied NOTE Use only Teflon tape without adhesive backing to seal joints Do not use pipe compound pipe dope sticks or similar compounds with this unit they contain petroleum derivatives which can cause crazing and cracking of the plastic in the filter housing NOTE Use only soap and water to clean components NOTE Do not use aerosol sp...

Страница 3: ...d to allow faucet base to rest securely The faucet fits through a 1 3 8 hole Most sinks have pre drilled 1 3 8 or 1 1 2 diameter holes that may be used for faucet installation If these pre drilled holes cannot be used or are in an inconvenient location it will be necessary to drill a 1 3 8 hole in the sink to accommodate the faucet WARNING This proceduremaygeneratedust which can cause severe irrit...

Страница 4: ...is tube should be long enough to reach the drain clamp in Step 7 Will Spring Open C Notch For Faucet Figure 4 45 Notch For Faucet Blades Must Be Held When Tightening E Locate the 1 4 red brine tube from the right side of the system head assembly Route the tube through the faucet base and connect to small barb on the faucet Make certain that the tube is not kinked or stressed once the head assembly...

Страница 5: ...INSTALLATION continued Figure 3 Model PB4RO 75 Undersink Reverse Osmosis System JA12 5 ...

Страница 6: ...e PB4RO 75 two screws are supplied to mount the head Measure up from the floor of the cabinet 14 1 2 This will provide clearance to change the cartridges The two screws will be 14 apart and level Screw the two screws into the wall Leave a gap between the screw head and the wall of 1 8 The backside of the system head has two slots that will fit over the screw heads and slide down to lock 14 Inches ...

Страница 7: ...t fitting B Gently pull back on the tubing to ensure it is connected properly If the tubing comes out of fitting cut a small section off of the tubing and reconnect NOTE Tubing may be quickly and easily removed from the fitting if necessary First turn off the water supply to the filter Open faucet then press in the collet around the fitting while pulling the tubing with your other hand Step 8 A 3 ...

Страница 8: ...amp from the drainpipe and enlarge the hole with a 3 8 drill bit Use a file to remove rough edges from the drilled hole D Make sure the black rubber gasket is adhered to the inside of the drain clamp and place the drain clamp assembly over the drilled hole Look through the hole and position the clamp so that the center of the clamp hole is slightly higher about 1 16 than the center of the drilled ...

Страница 9: ...e place every 1 2 mon th s T EMPER A T U R E R AN G E 40 1 00 F 4 4 3 7 8 C PR ESSUR E RAN G E 30 1 25 F 2 4 8 6 Bar For u se with Pentair Wat er models PB4RO 75 PP4RO 75 and PB5RO 75 1 2 3 Figure 13 A Make sure cold water faucet is off Figure 14 B Make sure tank valve is in the open position C Slowly turn on cold water supply D Open the faucet to turn on flow Let the faucet run drip for 12 hours ...

Страница 10: ......

Страница 11: ...nk valve on top of storage tank C Turn off water to the system at the cold water supply D Open drinking water faucet to relieve pressure E Locate blue tubing leading to your drinking water faucet Cut and insert the 3 8 x 3 8 x 3 8 9 5 x 9 5 x 9 5 mm compression or quick connect tee into the blue tubing Figure 15 Consult manufacturer s guidelines before installing the tee connection NOTE When cutti...

Страница 12: ...dge on the left side of the filter housing counter clockwise for a 1 4 of a turn and pull the cartridge out of the system If the system has any significant leaks see Troubleshooting C Push the new cartridge into the head until it can go no further D Twist the cartridge 1 4 turn clockwise until it snaps into place E Gently pull the cartridge straight out to ensure the cartridge is locked into place...

Страница 13: ...F Repeat Step E four times Model PB4RO 75 Undersink Reverse Osmosis System JA12 ...

Страница 14: ......

Страница 15: ...tting 8 Turn water supply on at the saddle valve and close drinking water faucet 9 Allow system to pressurize for several hours and check for leaks 10 Check for leaks after tank is fully pressurized 1 3 hours If leak persists call Technical Support Leaks at Quick Connect Fittings CAUTION The 1 4 red tubing connected to the top of the fourth cartridge has a flow restrictor installed The system will...

Страница 16: ...ing water faucet 5 Using an air pressure gauge adjust the pressure in the storage tank to 5 7 psi 6 Replace the blue cap 7 Open the saddle valve until it comes to a stop Let the system run 1 3 hours to fill the tank A full tank weighs approximately 33 pounds If performance has not improved call Technical Support Sudden Return of Taste and Odor If shortly after complete servicing noticeable taste a...

Страница 17: ...G Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts NOTE Substances that may be reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement ...

Страница 18: ...10 11 14 JA12 Model PB4RO 75 Undersink Reverse Osmosis System ...

Страница 19: ...rom water very well RO systems are very effective at removing pentavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine may not convert all the trivalent arsenic If you...

Страница 20: ......

Страница 21: ...ng is 27 40 Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed PB4RO 75 Production Rate 24 83 gpd The PB4RO 75 is Tested and Certified by NSF International against NSF ANSI Standard 42 and 58 for the red...

Страница 22: ...ltration LLC prior to the expiration of the warranty date at the customer s expense shipment pre paid 4 be accompanied by a letter detailing the Model Number Serial Number if any and a brief description of the problem TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW PENTAIR RESIDENTIAL FILTRATION LLC DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIE...

Отзывы: