Pentair Pool Products PB4RO-75 Скачать руководство пользователя страница 2

GENERAL PRECAUTIONS  

 

WARNING: 

Do not use with water that is 

microbiologically unsafe or of unknown 
quality without adequate disinfection before 
or after the system. Systems certified for 
cyst reduction may be used on disinfected 
waters that may contain filterable cysts.

 

WARNING: 

The PB4RO contains a replaceable RO 

membrane cartridge that is critical to the 
efficiency of the system. Replacement of the 
RO membrane cartridge should be with one 
of identical specifications, as defined by the 
manufacturer, to assure the same efficiency 
and contaminant reduction performance.

 

WARNING: 

The PB4RO contains a replaceable RO 

membrane cartridge, critical for the effective 
reduction of total dissolved solids. Product 
water should be tested periodically to verify 
that the system is working properly.

 

WARNING: 

The PB4RO is acceptable for treatment 

of influent concentrations of no more

 

than 27 mg/L nitrate and 3 mg/L nitrite in 
combination measured as N and is certified 
for nitrate/nitrite reduction only for water 
supplies with a pressure of 40 psig (280 kPa) 
or greater.

 

WARNING: 

The PB4RO shall only be used for arsenic 

reduction on chlorinated water supplies 
containing detectable residual free chlorine 
at the system inlet. Water systems using an 
in-line chlorinator should provide a one- 
minute chlorine contact time before the unit.

 

WARNING: 

The PB4RO will not protect against disease- 

causing bacteria or remove naturally- 
occurring harmless bacteria.

 

CAUTION 

The PB4RO must be protected against freezing 

which can cause the filter housing to crack, 
resulting in water leakage.

 

CAUTION  

Turn  off  water  supply  to  head  without  cartridge  if 

it must  be left   unattended  for  an  extended  period 
of   time.

 

CAUTION  

Do  not  use  electrical  heating tape  on  this  unit. 

NOTE:   Substances   listed   as   reduced   are   not   necessarily

 

in your water. System must be maintained

 

according to manufacturer's instructions, including

 

replacement of filter cartridges.

 

NOTE: Your water must be within required limits for 

satisfactory operation. If not, the RO membrane 
cartridge’s life may be shortened and your warranty 
will be voided (see Operating Specifications).

 

NOTE: Install on cold water line only.

 

NOTE: Do not install where system will be exposed to 

direct sunlight.

 

NOTE: Make certain that installation complies with all state

 

and local laws and regulations.

 

NOTE: The filter cartridges and RO membrane cartridge 

included with the system have limited service lives. 
Changes in taste, odor, and color of the filtered 
water indicate that the cartridges and/or membrane 
should be replaced.

 

NOTE: During extended periods of non-use (such as 

during a vacation), remove the membrane cartridge 
and the filter cartridges from the unit and place 
them in a sealed plastic bag. Store the cartridges

 

in the refrigerator for future use. When re-starting 
the unit, replace all cartridges and flush per 
instructions.

 

 

 

NOTE: If the PB4RO stands for more than 2 to 3 days 

without being used, the storage tank should be 
emptied.

 

NOTE: Use only Teflon

® 

tape without adhesive backing 

to seal joints. Do not use pipe compound (“pipe 
dope”), sticks, or similar compounds with this

 

unit; they contain petroleum derivatives which can 
cause crazing and cracking of the plastic in the 
filter housing.

 

NOTE: Use only soap and water to clean components.

 

NOTE: Do not use aerosol sprays (bug spray, cleaning 

fluids, etc.) near the PB4RO. They contain organic 
solvents which will cause crazing and cracking of 
the plastic in the filter housing.

 

NOTE: After prolonged periods of non-use, such as a 

vacation, it is recommended that the system be 
flushed thoroughly. Let water run for 2 to 3 minutes 
before using.

 

NOTE: Do not use a torch near the unit.

 

 

HOW REVERSE OSMOSIS (RO) WORKS

 

The PB4RO uses a semi-permeable membrane to reduce 
dissolved salts, improving the taste and odor of your water. The 
RO membrane cartridge contains multiple layers of micron-thin 
film wound around a hollow center core. Water molecules can 
pass through the cartridge, while dissolved salts are rejected.

 

Your household water supply is pre-filtered to reduce dirt and 
chlorine that may foul the membrane. The RO membrane 
cartridge separates this pre-filtered water into PRODUCT 
WATER and REJECT WATER. Your household water pressure 
forces water through the membrane within the RO membrane 
cartridge, and into the storage tank. This is product water. 
Dissolved salts cannot pass through the membrane and are 
sent to the drain as reject water. When you open the faucet, 
product water (permeate) is drawn from the storage tank 
through a post-polishing filter. The post-polishing filter takes out 
any remaining taste or odor in the water and provides you and 
your family with cleaner, great-tasting water.

 

The PB4RO also features an auto shut-off valve, which shuts 
off the system once the pressure in the storage tank reaches 
2/3 of the incoming water pressure (your household water 
pressure). When you open the faucet to draw water from

 

the storage tank, the pressure inside the tank drops and 
the auto shut-off valve opens. The system then begins to

 

operate, replenishing the water you took from the storage tank. 
Depending on the system's efficiency, for each gallon of water 
produced, up to 7 gallons are discharged as reject water. The 
storage tank can hold up to 3.2 gallons (12.1 L) of water at a 
time, more than enough for the average family’s drinking and 
cooking needs.

 

NOTE: When used under operating conditions specified 

on page 1 of this manual, the RO membrane 
cartridge of the PB4RO should last 12–24 months.

 

The precise life span of the PB4RO's RO membrane 
cartridge will depend on the quality of the water 
entering the system, and the frequency with which 
you use it. Frequent use prevents the dissolved 
salts from building up on the membrane as scale. 
The more water the system is required to produce, 
the longer the membrane will last. You may wish

 

to find a variety of uses for your PB4RO system in 
order to prolong the life of the membrane.

 

2 • JA12 Model PB4RO-75 Undersink Reverse Osmosis System

 

 

Содержание PB4RO-75

Страница 1: ...or future reference Tools Required for plastic tubing Optional Materials hillips Screwdrivers rill Bits 1 8 1 4 and 3 8 owel afety Glasses ape Measure For sinks without extra hole for faucet enter punch espirator 3 8 Bi metal or Carbide Tipped Hole saw NOTE All tools listed will not be necessary for installation Read installation procedures before starting to determine required tools Parts Include...

Страница 2: ... than 2 to 3 days without being used the storage tank should be emptied NOTE Use only Teflon tape without adhesive backing to seal joints Do not use pipe compound pipe dope sticks or similar compounds with this unit they contain petroleum derivatives which can cause crazing and cracking of the plastic in the filter housing NOTE Use only soap and water to clean components NOTE Do not use aerosol sp...

Страница 3: ...d to allow faucet base to rest securely The faucet fits through a 1 3 8 hole Most sinks have pre drilled 1 3 8 or 1 1 2 diameter holes that may be used for faucet installation If these pre drilled holes cannot be used or are in an inconvenient location it will be necessary to drill a 1 3 8 hole in the sink to accommodate the faucet WARNING This proceduremaygeneratedust which can cause severe irrit...

Страница 4: ...is tube should be long enough to reach the drain clamp in Step 7 Will Spring Open C Notch For Faucet Figure 4 45 Notch For Faucet Blades Must Be Held When Tightening E Locate the 1 4 red brine tube from the right side of the system head assembly Route the tube through the faucet base and connect to small barb on the faucet Make certain that the tube is not kinked or stressed once the head assembly...

Страница 5: ...INSTALLATION continued Figure 3 Model PB4RO 75 Undersink Reverse Osmosis System JA12 5 ...

Страница 6: ...e PB4RO 75 two screws are supplied to mount the head Measure up from the floor of the cabinet 14 1 2 This will provide clearance to change the cartridges The two screws will be 14 apart and level Screw the two screws into the wall Leave a gap between the screw head and the wall of 1 8 The backside of the system head has two slots that will fit over the screw heads and slide down to lock 14 Inches ...

Страница 7: ...t fitting B Gently pull back on the tubing to ensure it is connected properly If the tubing comes out of fitting cut a small section off of the tubing and reconnect NOTE Tubing may be quickly and easily removed from the fitting if necessary First turn off the water supply to the filter Open faucet then press in the collet around the fitting while pulling the tubing with your other hand Step 8 A 3 ...

Страница 8: ...amp from the drainpipe and enlarge the hole with a 3 8 drill bit Use a file to remove rough edges from the drilled hole D Make sure the black rubber gasket is adhered to the inside of the drain clamp and place the drain clamp assembly over the drilled hole Look through the hole and position the clamp so that the center of the clamp hole is slightly higher about 1 16 than the center of the drilled ...

Страница 9: ...e place every 1 2 mon th s T EMPER A T U R E R AN G E 40 1 00 F 4 4 3 7 8 C PR ESSUR E RAN G E 30 1 25 F 2 4 8 6 Bar For u se with Pentair Wat er models PB4RO 75 PP4RO 75 and PB5RO 75 1 2 3 Figure 13 A Make sure cold water faucet is off Figure 14 B Make sure tank valve is in the open position C Slowly turn on cold water supply D Open the faucet to turn on flow Let the faucet run drip for 12 hours ...

Страница 10: ......

Страница 11: ...nk valve on top of storage tank C Turn off water to the system at the cold water supply D Open drinking water faucet to relieve pressure E Locate blue tubing leading to your drinking water faucet Cut and insert the 3 8 x 3 8 x 3 8 9 5 x 9 5 x 9 5 mm compression or quick connect tee into the blue tubing Figure 15 Consult manufacturer s guidelines before installing the tee connection NOTE When cutti...

Страница 12: ...dge on the left side of the filter housing counter clockwise for a 1 4 of a turn and pull the cartridge out of the system If the system has any significant leaks see Troubleshooting C Push the new cartridge into the head until it can go no further D Twist the cartridge 1 4 turn clockwise until it snaps into place E Gently pull the cartridge straight out to ensure the cartridge is locked into place...

Страница 13: ...F Repeat Step E four times Model PB4RO 75 Undersink Reverse Osmosis System JA12 ...

Страница 14: ......

Страница 15: ...tting 8 Turn water supply on at the saddle valve and close drinking water faucet 9 Allow system to pressurize for several hours and check for leaks 10 Check for leaks after tank is fully pressurized 1 3 hours If leak persists call Technical Support Leaks at Quick Connect Fittings CAUTION The 1 4 red tubing connected to the top of the fourth cartridge has a flow restrictor installed The system will...

Страница 16: ...ing water faucet 5 Using an air pressure gauge adjust the pressure in the storage tank to 5 7 psi 6 Replace the blue cap 7 Open the saddle valve until it comes to a stop Let the system run 1 3 hours to fill the tank A full tank weighs approximately 33 pounds If performance has not improved call Technical Support Sudden Return of Taste and Odor If shortly after complete servicing noticeable taste a...

Страница 17: ...G Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts NOTE Substances that may be reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement ...

Страница 18: ...10 11 14 JA12 Model PB4RO 75 Undersink Reverse Osmosis System ...

Страница 19: ...rom water very well RO systems are very effective at removing pentavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine may not convert all the trivalent arsenic If you...

Страница 20: ......

Страница 21: ...ng is 27 40 Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed PB4RO 75 Production Rate 24 83 gpd The PB4RO 75 is Tested and Certified by NSF International against NSF ANSI Standard 42 and 58 for the red...

Страница 22: ...ltration LLC prior to the expiration of the warranty date at the customer s expense shipment pre paid 4 be accompanied by a letter detailing the Model Number Serial Number if any and a brief description of the problem TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW PENTAIR RESIDENTIAL FILTRATION LLC DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIE...

Отзывы: