TROUBLESHOOTING continued
Limited Flow at Drinking Water Faucet
1. Turn off water supply to system at saddle valve.
2. Open the faucet to turn on flow.
3. Unscrew the blue cap at the base of the storage tank to
expose air valve. Use a small air compressor or bicycle
pump to add air to the storage tank. This will force the
water out of the storage tank through the faucet.
Continue to add air until no more water comes out of the
faucet.
4. Turn off the drinking water faucet.
5. Using an air pressure gauge, adjust the pressure in the
storage tank to 5–7 psi.
6. Replace the blue cap.
7. Open the saddle valve until it comes to a stop. Let the
system run 1–3 hours to fill the tank. A full tank weighs
approximately 33 pounds. If performance has not improved,
call Technical Support.
Sudden Return of Taste and Odor
If shortly after complete servicing, noticeable taste and odors
return, contact Technical Support.
If you are experiencing a problem not listed in this manual,
shut off the water supply at the saddle valve and close the tank
valve. Call Technical Support.
12 • JA12 Model PB4RO-75 Undersink Reverse Osmosis System