14
ENGLISH
Step 3
Assemble the system again carefully in reverse order. To do
so, insert two feet of the pump into the holding fixtures in the
tank floor and carefully place the float lever in the float switch
bracket. Test whether this is firmly secured in place by turn
-
ing the pump handle gently from side to side. Place the flexible
discharge elbow onto the discharge branch as far as it will go
and tighten the wing bolts of the hose clamp by hand. Check
that these components work by moving the float switch up and
down by hand. Press the lid down onto the tank and hand tight-
en the screws in the brackets in a crosswise order. To prevent a
collision between the cable and the movable parts in the tank,
draw the cable out of the tank as far as possible and securely
tighten the cable gland.
TECHNICAL DATA
Weight 6.2 kg
Pressure branch DN 32
Motor power P1 320 W
Motor power P2 200 W
Voltage 1/N/PEx230 V
Frequency 50 Hz
Rated current 1.4 A
Type of enclosure Plug unit IP 20
Control voltage for alarm circuit 12 V DC (SELV)
UK: Fuse in the plug = 13 A
Performance
H
[m]
1
2
3
4
5
6
Q
[m³/h]
6,5
5,5
5,0
4,0
3,0
1,5