SGM700 Digitizer
Configuration Menu -dAC- -continue-
The options are:
For further detais on the weigher functions check appendix I
The following screen will be vissable:
In
dAC 5
you set the
weigher start value
for the analog output. At this value the
analog output starts with its minimum value. Press key 2 < 2sec. to enter dAC 5.
Fill in the wanted start weight using key 1 and key 2. Key 1 is for changing the
number (1-9), key 2 is for changing the position of the cursor.
Confirm by pressing key 3 >2 sec.
Increase Decrease Left Right Confirm
28
1 Weigher
10 Fast gross x 10
2 Fast gross
11 Fast Net x 10
3 Fast net
12 Gross x 10
4 Gross
13 Net x 10
5 Net
14 Tare x 10
6 Tare
15 Peak x 10
7 Peak
16 Valley x 10
8 Valley
17 Sample
9 Weigher x 10