background image

of sealant into the three sill strike holes and install the three # 8 x 3" fl at head stainless 
steel screws (provided) into the holes.  

K.  

Shim between the frame and the rough opening at the head strike location and 

at every frame anchor hole location.

 

Remove and replace head strike screws 
with three #8 x 3" corrosion resistant screws 
(provided) through the head strike, door 
frame, shims and into the rough opening. 

Note: For doors with no head strike check 
head for pre-drilled installation holes. If 
installation holes are present drill 1/8" 
pilot in each installation hole and install a 
#8 x 3" screw (provided).

L.  

On each hinge, starting at the top,

 insert 

a corrosion resistant screw (#12 x 2-1/2" for 
out-swing  or #8 x 3" for in-swing; provided) 

DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS

into the open screw hole. Make sure the 
screw passes through the shims and into the 
structural framing. 

M. 

Check door operation. 

Open and close 

the door to check for proper operation. 
Make sure the door will latch correctly.

Note: If there are any problems with 
the operation, check to confi rm the 
door frame is installed plumb, level 
and square. If the reveal between the 
door panel(s) and frame is not even, 
adjustments may be made: 

 

Doors WITHOUT adjustable hinges:

 

Plastic shims located behind the hinges 
may be removed to adjust the reveal 
between the door panel and door frame. 
Additional hinge shims may be added
if required.

Adjustable 

Hinge

Non-Adjustable 

Hinge

Note: Doors with adjustable hinges will have a (+)(-) on the door panel hinge 
leaf to indicate possible adjustments and doors without adjustable hinges 
do not have  adjustment indicators. 

Adjustable hinges are not designed to make up for failure to install the door 
frame correctly. Before adjusting hinges, confi rm the door is installed plumb, 
level and square.

Interior 

3K

3J

3K

3J

Interior

3L

Содержание 818K0100

Страница 1: ...her construction methods multiple units or bow and bay windows may be obtained from Pella Corporation or a local Pella retailer or by visiting http www pella com Building designs construction methods...

Страница 2: ...ers 2 Phillips with 8 shaft and small at blade T20 Torx Wrench Drill Drill bits 13 64 and 1 8 and masonry bit for concrete applications INSTALLATION CLIP OPTION 6 or 8 installation clips 6 x 5 8 corro...

Страница 3: ...Apply sill ashing tape 1 Cut a piece of ashing tape 12 longer than the opening width Apply at the bottom of the opening as shown 1E so it overhangs 1 to the exterior Note The tape is cut 12 longer tha...

Страница 4: ...g tape to the width of the opening Install to the anges of the sill pan and overlap the tape from step 1N by 1 If needed add a second or third piece of ashing tape until the sill pan is covered to the...

Страница 5: ...ons for Performance Upgrade and HurricaneShield product requires additional clip installation or screw installation Clip installation prep is included in Step 2B Screw installation steps are included...

Страница 6: ...of sealant Place the rst bead of sealant 1 2 from the base of the interior sill pan lip This bead should also continue up the corner of the sill pan at each end sealing the vertical joints of the sil...

Страница 7: ...ly open the door s and remove all shipping spacers Note Be sure to remove the spacers from the bottom edge of the door panel Use the construction handle to operate both the active and passive door pan...

Страница 8: ...the open screw hole Make sure the screw passes through the shims and into the structural framing M Check door operation Open and close the door to check for proper operation Make sure the door will l...

Страница 9: ...oximately 8 from the top of the door frame head Insert a 8 x 3 screw provided into the pilot hole making sure it passes through the shim and into the rough opening framing Note This step does not appl...

Страница 10: ...rough opening in the locations shown On hinge jambs clearance hole locations are centered between hinges Hinge Jambs See 5A In Swing diagram upper right Fixed and Lock jambs diagram for placement of t...

Страница 11: ...nufacturers s recommendations NOTE Not required on In swing Fixed doors Out Swing SILL HEAD Drill 1 8 diameter pilot holes through the clearance hole in the frame 5C 10 x 3 1 2 corrosion resistant woo...

Страница 12: ...into the space between the door and the rough opening and apply a 1 deep bead of foam This will allow room for expansion of the foam and will minimize squeeze out Apply sealant across the interior sur...

Страница 13: ...s with window and door materials and voids Limited Warranty For additional information on nishing see the Pella Owner s Manual or go to www pella com EXTERIOR FINISHING Wood doors require painting imm...

Страница 14: ...management of moisture within the wall systems The determination of the suitability of all building components including the use of Pella products as well as the design and installation of ashing and...

Страница 15: ...This page left blank intentionally...

Страница 16: ...This page left blank intentionally...

Отзывы: