background image

Exterior 

16d galvanized
finishing nails

D

Plumb and square door. 

Place shims at each hinge 

and lock strike location between the door and the sides 
of the opening. Keep shims back 1/2" from interior 
face of the door frame. Insert shims in other locations 
as needed starting up 6" from the bottom of the door 
to square it in the opening. Make sure that the reveal 
around the door(s) is equal. On double doors, make 
sure that panels are even across the bottom.

Note: On center latch double doors the lock strike 
will not be shimmed since it is located in the center 
of the unit. DO NOT over shim.

DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS •

 ALL

 DOORS

E.  

Check the interior reveal.

 Make 

sure the measurement from the 
interior face of the door to the 
interior  face of the wall is equal 
at several points around the door. 
And the door is plumb in the 
opening. It may be necessary to 
shim between the wall and the 
brickmould to ensure the door is 
plum during the remainder of the 
installation steps. 

F. 

Fasten the door to opening

 

by driving 16d galvanized 
fi nishing nails through the 
brickmould or fl at casing 6" 
from each corner and not 
more than 10" on center.

G. 

Carefully open the door(s)

 and remove all 

shipping spacers.

Note: Be sure to remove the spacers from 
the bottom edge of the door panel. Use the 
construction handle to operate both the active 
and passive door panels.

H.  

For Out-Swing Standard Installation Applications Only:  Install sill screws.

 

Remove the threshold screws and insert a #8 x 3" stainless steel screw (provided) 
into each hole. For masonry fl oors use a 3/16 masonry screw in place of the 
provided screw, pilot drill per screw manufacturer’s recommendations.

Note: On In-Swing Door Standard Installation, sill screws are not needed. 

 

SILL SCREWS FOR ARCHITECT SERIES PERFORMANCE UPGRADE AND 
DOORS WITH HURRICANESHIELD IMPACT-RESISTANT GLASS ARE 
INSTALLED IN STEP 5. 

I.  

For Low Profi le Sills through each installation screw hole drill a 1/8" pilot; 

and 

install a #8 x 3" corrosion resistant screw (provided) into the pilot hole into the fl oor. 
For doors including a standard lock install tubs per instruction included with the sill 
strike package. 

Note: For concrete fl oors use masonry screws that are a minimum size of 3/16" 
diameter x 2" and pilot per manufacturer’s recommendations for the screw. 

J.  

Remove sill strike screws from the sill strike located on the door sill.

 Place a dab 

&YUFSJPS

Ó

3D

Interior

3D

3D

3D

1

2 0 3 0 40

5 0 6 0 70

2

3

INCHES

mm

3E

Double door with Center Latch:

 Use the construction handle to operate both the 

active and passive door panels. 

3F

3H

Содержание 818K0100

Страница 1: ...her construction methods multiple units or bow and bay windows may be obtained from Pella Corporation or a local Pella retailer or by visiting http www pella com Building designs construction methods...

Страница 2: ...ers 2 Phillips with 8 shaft and small at blade T20 Torx Wrench Drill Drill bits 13 64 and 1 8 and masonry bit for concrete applications INSTALLATION CLIP OPTION 6 or 8 installation clips 6 x 5 8 corro...

Страница 3: ...Apply sill ashing tape 1 Cut a piece of ashing tape 12 longer than the opening width Apply at the bottom of the opening as shown 1E so it overhangs 1 to the exterior Note The tape is cut 12 longer tha...

Страница 4: ...g tape to the width of the opening Install to the anges of the sill pan and overlap the tape from step 1N by 1 If needed add a second or third piece of ashing tape until the sill pan is covered to the...

Страница 5: ...ons for Performance Upgrade and HurricaneShield product requires additional clip installation or screw installation Clip installation prep is included in Step 2B Screw installation steps are included...

Страница 6: ...of sealant Place the rst bead of sealant 1 2 from the base of the interior sill pan lip This bead should also continue up the corner of the sill pan at each end sealing the vertical joints of the sil...

Страница 7: ...ly open the door s and remove all shipping spacers Note Be sure to remove the spacers from the bottom edge of the door panel Use the construction handle to operate both the active and passive door pan...

Страница 8: ...the open screw hole Make sure the screw passes through the shims and into the structural framing M Check door operation Open and close the door to check for proper operation Make sure the door will l...

Страница 9: ...oximately 8 from the top of the door frame head Insert a 8 x 3 screw provided into the pilot hole making sure it passes through the shim and into the rough opening framing Note This step does not appl...

Страница 10: ...rough opening in the locations shown On hinge jambs clearance hole locations are centered between hinges Hinge Jambs See 5A In Swing diagram upper right Fixed and Lock jambs diagram for placement of t...

Страница 11: ...nufacturers s recommendations NOTE Not required on In swing Fixed doors Out Swing SILL HEAD Drill 1 8 diameter pilot holes through the clearance hole in the frame 5C 10 x 3 1 2 corrosion resistant woo...

Страница 12: ...into the space between the door and the rough opening and apply a 1 deep bead of foam This will allow room for expansion of the foam and will minimize squeeze out Apply sealant across the interior sur...

Страница 13: ...s with window and door materials and voids Limited Warranty For additional information on nishing see the Pella Owner s Manual or go to www pella com EXTERIOR FINISHING Wood doors require painting imm...

Страница 14: ...management of moisture within the wall systems The determination of the suitability of all building components including the use of Pella products as well as the design and installation of ashing and...

Страница 15: ...This page left blank intentionally...

Страница 16: ...This page left blank intentionally...

Отзывы: