Installation and Operating Manual
Page 14
ADJUSTING THE DRYING PROGRAMMES
The drying cabinet’s automatic programmes can be optimised in relation to the existing installation
conditions. This is done by adjusting the parameter values for the automatic programme concerned on
the control panel. This is only to be done if you find that:
The washing is not dried sufficiently or,
The washing is over
-
dried.
Calibrating Sensors:
NOTE.
It is important that the cabinet is at room temperature when calibrating..
To calibrate sensors, turn off the cabinet and ensure there is no load inside. Go to the parameter list,
choose parameter
P400
and set it to the value 1. A calibration cycle will then start which takes around 5
minutes. When the sensors have been calibrated, the cabinet will re
-
start automatically.
Drying Programme
Parameter
ECO+
2165
LOW
2233
LOW EXTRA DRY
2243
HIGH
2203
HIGH EXTRA DRY
2213
HIGH ECO
2273
Parameters to Adjust:
·
If you find the washing is under
-
dried,
increase the parameter value
for the relevant programme
·
If you find the washing is over
-
dried,
decrease the parameter value
for the relevant programme
Please see the table below for the parameter of the programme that requires adjusting.
Access to Parameters:
·
Turn the cabinet off by pressing the
ON/OFF
button.
·
Hold down
START/STOP
and then press the
ON/OFF
button again. Select parameter by stepping up or down
using + /
-
.
Adjusting Parameters:
·
When the desired parameter has been selected, press
START/STOP
to go to the parameter concerned.
·
Adjust the parameter by stepping up or down using + /
-
·
Press
START/STOP
to leave parameter adjustment.
Leaving the Parameter List:
·
When you have adjusted the parameters you want,
press
MAN
and
START/STOP.
·
If you want to reset the parameters to the factory set-
ting, press
AUTO
and
START/STOP.
CARE
The inside and outside of the cabinet should be
cleaned with a mild soap solution and a damp
cloth.
Dust will collect on the top of the cabinet,
especially around the air intake. This can cause
operational faults within the cabinet, as well as
pose a fire hazard.
To avoid any potential problems, the top of the
cabinet should be vacuum cleaned at least once
a year, or more frequently depending on the
location of the cabinet and its application.
CLEANING
NOTE.
High
-
pressure cleaning should
not
be used.