Cleaning
Clean the outside of the generator only using warm soapy water and a clean damp
cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.
Cleaning should only be undertaken with the power switched off and
the power cord removed from the rear of the generator.
Under no circumstances should any solvents or abrasive cleaning
solutions be used as these can contain fumes that could be harmful to
the generator.
Care should be taken with Leak Detections Liquids.
Safely Isolated Condition
The unit is in a safely isolated condition when it is disconnected from its application
and fully de-pressurised. Directions for isolating the Generator are shown below.
Failure to place the Generator in a safely isolated condition when
instructed to do so may lead to personal injury or injury to others and
even death.
1. Switch generator off.
2. Disconnect from air supply.
3. Ensure the output pressure gauge reads zero. (If gauge does not fall to zero, open
the manual ball valve at the outlet port, to allow trapped gas to escape.)
4. Disconnect from the application.
Safe State After Repair
To guarantee the generator is in a safe state after a repair, please ensure the following
conditions are met;
• All earth leads have been reconnected.
Earth leads should be connected to the earth tabs located on the door panels, as
shown below.
• The electricity cable has been correctly refitted.
The mains cable should be plugged into the IEC power inlet located on the rear
panel of the generator.
This unit is classified as SAFETY CLASS 1. THIS UNIT MUST
BE EARTHED.
CAUTION
CAUTION
WARNING