12
A. WATER TEMPERATURE CONTROLS
A periodic inspection of the operating controls, heat
exchanger and wiring should be made by qualified service
personnel.
Temperature of the water should be tested periodically at the
faucet to be sure thermostat is working properly.
B. TEMPERATURE CONTROL
The water heater is delivered with an ETC101 thermostat. A
factory set temperature setting of 120
F and differential
setting of 10
F. Any temperature adjustment of the
thermostat must be made by qualified service personnel, as
shown below.
WARNING: See WATER TEMPERATURE REGULATION,
regarding safe water temperature before proceeding. Hot
water can cause scalding injuries.
Shut off or disconnect all electrical supply to heater.
Remove cover to Thermostat.
Adjust right side lever to the desired temperature. Moving
lever down will decrease temperature.
(See THERMOSTAT
DIAGRAM 1). NOTE: Markings on slide are approximate.
Check temperature at faucet to ensure safe operating
temperature.
Adjust left side lever to the desired differential. The
thermostat will call for heat when the tank temperature has
fallen to the set differential degrees below the Temperature
set point.
Reattach cover.
Reconnect electrical supply.
Check faucet temperature to verify desired temperature is
achieved.
In order to set the temperature above 140
F (
NOT
RECOMMENDED
) you must remove the SCALD DANGER label
attached to the temperature slide.
CAUTION: Do not increase temperature above 140° without a
properly installed mixing valve in the system
– See
WATER TEMPERATURE REGULATION and SCALD
WARNING.