Page 53
FIELDBUS PROTOCOL
The input area registers (written by the unit and read by the master), shared by all the PROFIBUS,
PROFINET, ETHERCAT, ETHERNET/IP fieldbuses, are listed in the following table.
The registers’ size is 16 bits. The input area is updated at a fixed frequency of 125 Hz (80 Hz in case
of PROFIBUS fieldbus).
The size of the Input area configured in the master fieldbus should match with the size configured in
the unit.
INPUT DATA AREA
Bytes
Register
address
INPUT AREA REGISTER
Notes
1-2
0
Status Register
See relevant table.
3-4
1
Gross weight (MSW)
INT. value - Most significant word
5-6
2
Gross weight (LSW)
INT. value - Least significant word
7-8
3
Net weight (MSW)
INT. value - Most significant word
9-10
4
Net weight (LSW)
INT. value - Least significant word
11-12
5
Digital inputs
See relevant table.
13-14
6
Digital outputs
See relevant table.
15-16
7
Monitor register
This value corresponds to the equivalent register in the output
area.
17-18
8
Net weight of last weighing
performed (MSW)
INT. value - Most significant word
19-20
9
Net weight of last weighing
performed (LSW)r
INT. value - Least significant word
21-22
10
Code of last weighing
performed (MSW)
INT. value - Most significant word
23-24
11
Net weight of last weighing
performed (LSW)
INT. value - Least significant word
25-26
12
Cell of last weighing performed
INT. value - Da 0 a 1 (0 = cell channel A, 1 = cell channel B)
27-28
13
Set-Point 1, channel A (MSW)
INT. value - Most significant word
29-30
14
Set-Point 1, channel A (LSW)
INT. value - Least significant word
31-32
15
Set-Point 2, channel A (MSW)
INT. value - Most significant word
33-34
16
Set-Point 2, channel A (LSW)
INT. value - Least significant word
35-36
17
Set-Point 3, channel A (MSW)
INT. value - Most significant word
37-38
18
Set-Point 3, channel A (LSW)
INT. value - Least significant word
39-40
19
Set-Point 4, channel A (MSW)
INT. value - Most significant word
41-42
20
Set-Point 4, channel A (LSW)
INT. value - Least significant word
43-44
21
Set-Point 5, channel A (MSW)
INT. value - Most significant word
45-46
22
Set-Point 5, channel A (LSW)
INT. value - Least significant word
47-48
23
Set-Point 6, channel A (MSW)
INT. value - Most significant word
49-50
24
Set-Point 6, channel A (LSW)
INT. value - Least significant word
51-52
25
Set-Point 1, channel B (MSW)
INT. value - Most significant word
53-54
26
Set-Point 1, channel B (LSW)
INT. value - Least significant word
55-56
27
Set-Point 2, channel B (MSW)
INT. value - Most significant word
57-58
28
Set-Point 2, channel B (LSW)
INT. value - Least significant word
59-60
29
Set-Point 3, channel B (MSW)
INT. value - Most significant word
61-62
30
Set-Point 3, channel B (LSW)
INT. value - Least significant word