Page 17
MESSAGGE
DESCRIPTION
DEFAULT
RANGE
FIELDBUS ADDR.
SEtP. 1
Sets the value of Setpoint 1
0
0÷Capacity
201(MSB)
202(LSB)
SEtP. 2
Sets the value of Setpoint 2
0
0÷Capacity
203 (MSB)
204 (LSB)
SEtP. 3
Sets the value of Setpoint 3
0
0÷Capacity
205 (MSB)
206 (LSB)
SEtP. 4
Sets the value of Setpoint 4
0
0÷Capacity
207 (MSB)
208 (LSB)
SEtP. 5
Sets the value of Setpoint 5
0
0÷Capacity
209 (MSB)
210 (LSB)
SEtP. 6
Sets the value of Setpoint 6
0
0÷Capacity
211 (MSB)
212 (LSB)
The set-up value set points are compared against weight to drive the relevant logical output.
The comparator is selected in the set point set-up procedure.
When weight cannot be measured or is out of scale, all the outputs are disabled (open or
closed contact according to MODE set-up, see the corresponding section).
In the set point set-up phase, both outputs are disabled. If the saved value set point is 0, the
relevant output is never enabled, whatever the selected set point set-up.