background image

2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions arise during
installation or use of this product, please contact Patton Electronics
Technical Support at: (301) 975-1007.

2.1  FEATURES

• Synchronous data rates: 9.6, 19.2, 32, 56, 64 and 128 kbps in all

clock modes

• Asynchronous data rates: 0 - 38.4 kbps

• Full duplex operation over a one or two twisted pair (2- or 4-Wires)

• Point-to-point distances up to 5  miles (8Km) 

• Remote digital loopback, local line loopback diagnostics 

• Internal, external or receive recovered clocking options

• LED indicators for TD, RD, CTS, CD, DTR, TM, ER and NS

• Fits in Patton’s rack chassis and cluster boxes

• Made in the U.S.A.

2.2   DESCRIPTION

The Patton Model 1092RC 

KiloModem 2W

TM

baseband modem

allows synchronous or asynchronous data to be transmitted up to 5
miles (8 km) over one or two twisted pair (2 or 4 Wire).  Supporting
synchronous speeds up to 128 kbps and asynchronous speeds up to
38.4 kbps, the 1092RC is perfect for LAN interconnection or high speed
internet links.

Supporting 2B1Q encoding, Automatic Equalization and Auto Gain

Control, the Model 1092RC compensates for poor line quality.
Swappable interface driver boards and interface cards allow the user to
easily change applications between RS-232 and V.35.  Future driver
boards and interface cards will include X.21, G.703, and RS-530.  The
Model 1092RC also features convenient front panel diagnostic switches
and LEDs that allow for easy setup, configuration and  testing. 

The Model 1092RC is designed to fit into Patton’s 2U (3.5”) high

rack chassis

.  

This 16-card chassis has a switchable 120/240 VAC

power supply (optional 48 VDC) and mounts cards in a mid-plane
architecture:  The front card can be plugged into different rear cards.

4

APPENDIX B

PATTON MODEL 1092RC

FACTORY REPLACEMENT PARTS

AND ACCESSORIES

Patton Model #

Description

1000RCM12592.........Rear card w/DB25F & RJ45 (V.24 interface)
1000RCM12492.........Rear card w/ M/34F & RJ45 (V.35 interface)

1000RPEM ................120/240V Rear Power Entry Module
1000RPSM-2 .............120/240V Front Power Supply Module
1000RPEM-DC ..........DC Rear Power Entry Module
1000RPSM-48A.........48V Front Power Supply Module
1000RPEM-V.............120/240V CE Compliant Rear Power 

Entry Module

1000RPEM-V.............120/240V CE Compliant Rear Power 

Supply Entry Module

1000CC......................Control Card
IM1RC/A ....................Interface daughter card, V24/V.35
0805US......................American Power Cord
0805EUR ...................European Power Cord CEE 7
0805UK......................United Kingdom Power Cord
0805AUS ...................Australia/New Zealand Power Cord
0805DEN ...................Denmark Power Cord
0805FR ......................France/Belgium Power Cord
0805IN .......................India Power Cord
0805IS .......................Israel Power Cord
0805JAP ....................Japan Power Cord
0805SW .....................Switzerland Power Cord

33

Содержание 1092RC

Страница 1: ...2 Wire Synchronous and Asynchronous Rack Mount Modem Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1092RC E Doc 033021U Rev F Revised 1 22 08 C E R T I F I...

Страница 2: ...ings 3 3 2 Model 1000RCM13492 Strap Settings 4 0 Installation 24 4 1 The Model 1000R16P Rack Chassis 4 1 1 The Rack Power Supply 4 2 Installing the Model 1092RC Series Into Chassis 4 3 1 Connecting to...

Страница 3: ......

Страница 4: ...r This number may be obtained from Patton Electronics Technical Support tel 301 975 1007 email support patton com www http www patton com NOTE Packages received without an RMA number will not be accep...

Страница 5: ......

Страница 6: ...r board strap and two eight position DIP switches on the front card see Figure 1 below Figure 2 shows the orientation of the DIP switches with respect to the ON and OFF positions 5 ON 1 2 3 4 5 6 7 8...

Страница 7: ......

Страница 8: ...te On On 32 Kbps Reserved Off On 56 Kbps Reserved On Off 64 Kbps Reserved Off Off 19 2 or 128 Kbps 0 38 4 kbps NOTE Model 1092RC operates either at a synchronous rate of 19 2 kbps or 128 kbps dependin...

Страница 9: ......

Страница 10: ...see Appendix B In order to configure the Model 1092RC by software commands you must set its control port address The control port address is defined by a two digit decimal number Switches S2 1 throug...

Страница 11: ......

Страница 12: ...n Appendix D Refer to Appendix C to order a pre made cable 2 Power up the terminal and set its RS 232 port as follows 9600 Baud 8 data bits i stop bit no parity Local echo CR CR LF on inbound data ANS...

Страница 13: ......

Страница 14: ...nfiguration Select Option 4 toedit the software configuration of the Model 1092RC To save changes after editing the software configuration select MAIN MENU Option 5 then select Use Software Switches a...

Страница 15: ......

Страница 16: ...odel 1092RC to either respond or ignore the Remote Digital Loop request from the remote 1092RC 6 DTE Controlled Local Line Loop Select Option 6 in the SOFTWARE CONFIGURATION Menu to instruct the Model...

Страница 17: ......

Страница 18: ...ption 7 Test Modes Select Option 7 from the MAIN MENU to select the test mode status of the Model 1092RC below The Model 1092RC Test Mode settings help to verify the integrity of the data link and iso...

Страница 19: ......

Страница 20: ...ious parameters in the remote Model 1092RC 19 REMOTE UNIT CONFIGURATION MAIN MENU 1 Display Remote Unit Configuration 2 Setup Remote Unit Configuration 3 Display Remote Modem Status 4 Select Hardware...

Страница 21: ......

Страница 22: ...function cards Prior to installation you will need to examine the rear card you have selected and make sure it is properly configured for your application Each rear card is configured by setting strap...

Страница 23: ......

Страница 24: ...RCM13492 Strap Settings Figure 7 shows the strap location for the Model 1000RCM13492 M 34 RJ 45 rear card This strap determines whether Signal Ground and Frame Ground will be connected SGND FRGND JB4...

Страница 25: ......

Страница 26: ...the rack chassis and plug into each other by way of mating 50 pin card edge connectors Use the following steps as a guideline for installing each Model 1092RC Series into the rack chassis 1 Slide the...

Страница 27: ......

Страница 28: ...N SIGNAL TIP 4 4 TIP RING 5 5 RING 4 3 5 Connection to the Control Port Interface Please refer to the Model 1000CC Control Card user manual for cable requirements of the Control Port Interface 27 Noti...

Страница 29: ......

Страница 30: ...ese tests can be activated physically from the front panel or via the interface 5 2 1 Using Local Line Loopback LLB The Local Line Loopback LLB test checks the operation of the local Model 1092RC and...

Страница 31: ......

Страница 32: ...sent move the V 52 toggle switch to the right activating the 511 E test with errors present If the test is working properly the local modem s red ER LED will glow A successful 511 E test will confirm...

Страница 33: ......

Страница 34: ...1000RPSM 48A 48V Front Power Supply Module 1000RPEM V 120 240V CE Compliant Rear Power Entry Module 1000RPEM V 120 240V CE Compliant Rear Power Supply Entry Module 1000CC Control Card IM1RC A Interfac...

Страница 35: ......

Страница 36: ...Signal 1 FG Frame Ground 2 TD Transmit Data 3 RD Receive Data 4 RTS Request to Send 5 CTS Clear to Send 6 DSR Data Transfer Rate 7 SGND Signal Ground 15 TC Test Control A 17 RC Receive Timing 18 LLB L...

Страница 37: ......

Страница 38: ...NMENT RJ45 Connector Pin Number Signal 1 N C No Connection 2 N C No Connection 3 N C No Connection 4 Tip 5 Ring 6 N C No Connection 7 N C No Connection 8 N C No Connection Copyright 1997 Patton Electr...

Страница 39: ......

Страница 40: ......

Отзывы: