3.1.1  Reversible Interface Driver Board

The Model 1092RC Series features switchable interface driver

boards that allow  a wide range of DTE interface connections.  Each
interface driver board incorporates  two interfaces -- one on each side
of the driver board.  Figure 3 shows the Interface Driver Board on the
bottom of the 1092RC PC board. 

Follow the instructions below to select the correct interface for your

application:

1.   With the 1092RC pulled out of the rack or clusterbox chassis, 

locate the driver board on the top of the 1092RC front card.

2.   Lift the interface board gently off of the PC board.

3.   Locate the correct interface on the bottom of the driver board.  

For example, the RS-232/V.35 interface board is marked

“THIS SIDE UP FOR RS-232”

on one side and 

“THIS SIDE

UP FOR V.35”

on the other side

.

4.   Re-orient the interface board into the socket with the

appropriate interface pointed UP and with the arrow pointing
toward the front panel of the Model 1092RC PC board.

5.   Push the Interface Driver Board gently onto the socket and re-

install into the rack or cluster system.

6

Figure 3.

Closeup of Model 1092RC Interface Driver Board

ON

12345678

ON

12345678

Interface
Driver
Board

FRONT

THIS SIDE UP FOR V.35

5.2.3  Using the V.52 (BER) Test Pattern Generator

To use the V.52 BER tests in conjunction with the Remote Digital

Loopback tests* (or with Local Line Loopback tests), follow these
instructions:

1.

Locate the “511/511E” toggle switch on the front panel of the 
1092RC and move it to the left.  This activates the V.52 BER 
test mode and transmits a “511” test pattern into the loop.  If 
any errors are present, the local modem’s red “ER” LED will 
blink sporadically.  

2.   If the above test indicates no errors are present, move the 

V.52 toggle switch to the right, activating the “511/E” test with 
errors present.  If the test is working properly, the local 
modem's red “ER” LED will glow.  A successful “511/E” test 
will confirm that the link is in place, and that the Model 
1092RC’s built-in “511” generator and detector are working 
properly.

*NOTE:

The above V.52 BER tests can be used independently of

the Remote Digital Loopback tests.  This requires two operators:
one to initiate and monitor the tests at the local

Model 1092RC,

and one to do the same at the remote Model 1092RC.  In this
case, the test pattern sent by each Model 1092RC will not be
looped back, but will be transmitted down the line to the other
Model 1092RC.  

31

Содержание 1092RC

Страница 1: ...2 Wire Synchronous and Asynchronous Rack Mount Modem Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1092RC E Doc 033021U Rev F Revised 1 22 08 C E R T I F I...

Страница 2: ...ings 3 3 2 Model 1000RCM13492 Strap Settings 4 0 Installation 24 4 1 The Model 1000R16P Rack Chassis 4 1 1 The Rack Power Supply 4 2 Installing the Model 1092RC Series Into Chassis 4 3 1 Connecting to...

Страница 3: ......

Страница 4: ...r This number may be obtained from Patton Electronics Technical Support tel 301 975 1007 email support patton com www http www patton com NOTE Packages received without an RMA number will not be accep...

Страница 5: ......

Страница 6: ...r board strap and two eight position DIP switches on the front card see Figure 1 below Figure 2 shows the orientation of the DIP switches with respect to the ON and OFF positions 5 ON 1 2 3 4 5 6 7 8...

Страница 7: ......

Страница 8: ...te On On 32 Kbps Reserved Off On 56 Kbps Reserved On Off 64 Kbps Reserved Off Off 19 2 or 128 Kbps 0 38 4 kbps NOTE Model 1092RC operates either at a synchronous rate of 19 2 kbps or 128 kbps dependin...

Страница 9: ......

Страница 10: ...see Appendix B In order to configure the Model 1092RC by software commands you must set its control port address The control port address is defined by a two digit decimal number Switches S2 1 throug...

Страница 11: ......

Страница 12: ...n Appendix D Refer to Appendix C to order a pre made cable 2 Power up the terminal and set its RS 232 port as follows 9600 Baud 8 data bits i stop bit no parity Local echo CR CR LF on inbound data ANS...

Страница 13: ......

Страница 14: ...nfiguration Select Option 4 toedit the software configuration of the Model 1092RC To save changes after editing the software configuration select MAIN MENU Option 5 then select Use Software Switches a...

Страница 15: ......

Страница 16: ...odel 1092RC to either respond or ignore the Remote Digital Loop request from the remote 1092RC 6 DTE Controlled Local Line Loop Select Option 6 in the SOFTWARE CONFIGURATION Menu to instruct the Model...

Страница 17: ......

Страница 18: ...ption 7 Test Modes Select Option 7 from the MAIN MENU to select the test mode status of the Model 1092RC below The Model 1092RC Test Mode settings help to verify the integrity of the data link and iso...

Страница 19: ......

Страница 20: ...ious parameters in the remote Model 1092RC 19 REMOTE UNIT CONFIGURATION MAIN MENU 1 Display Remote Unit Configuration 2 Setup Remote Unit Configuration 3 Display Remote Modem Status 4 Select Hardware...

Страница 21: ......

Страница 22: ...function cards Prior to installation you will need to examine the rear card you have selected and make sure it is properly configured for your application Each rear card is configured by setting strap...

Страница 23: ......

Страница 24: ...RCM13492 Strap Settings Figure 7 shows the strap location for the Model 1000RCM13492 M 34 RJ 45 rear card This strap determines whether Signal Ground and Frame Ground will be connected SGND FRGND JB4...

Страница 25: ......

Страница 26: ...the rack chassis and plug into each other by way of mating 50 pin card edge connectors Use the following steps as a guideline for installing each Model 1092RC Series into the rack chassis 1 Slide the...

Страница 27: ......

Страница 28: ...N SIGNAL TIP 4 4 TIP RING 5 5 RING 4 3 5 Connection to the Control Port Interface Please refer to the Model 1000CC Control Card user manual for cable requirements of the Control Port Interface 27 Noti...

Страница 29: ......

Страница 30: ...ese tests can be activated physically from the front panel or via the interface 5 2 1 Using Local Line Loopback LLB The Local Line Loopback LLB test checks the operation of the local Model 1092RC and...

Страница 31: ......

Страница 32: ...sent move the V 52 toggle switch to the right activating the 511 E test with errors present If the test is working properly the local modem s red ER LED will glow A successful 511 E test will confirm...

Страница 33: ......

Страница 34: ...1000RPSM 48A 48V Front Power Supply Module 1000RPEM V 120 240V CE Compliant Rear Power Entry Module 1000RPEM V 120 240V CE Compliant Rear Power Supply Entry Module 1000CC Control Card IM1RC A Interfac...

Страница 35: ......

Страница 36: ...Signal 1 FG Frame Ground 2 TD Transmit Data 3 RD Receive Data 4 RTS Request to Send 5 CTS Clear to Send 6 DSR Data Transfer Rate 7 SGND Signal Ground 15 TC Test Control A 17 RC Receive Timing 18 LLB L...

Страница 37: ......

Страница 38: ...NMENT RJ45 Connector Pin Number Signal 1 N C No Connection 2 N C No Connection 3 N C No Connection 4 Tip 5 Ring 6 N C No Connection 7 N C No Connection 8 N C No Connection Copyright 1997 Patton Electr...

Страница 39: ......

Страница 40: ......

Отзывы: