Dear Customer

We thank you for choosing our product, with which you can burn different types of chopped fuels: 

pellets, washed peanuts, almond and hazelnut shells, blended corn, always obtaining high 

performance and maximum savings.

In this manual you will find all the information necessary to know the product, the assembly 

diagrams and the information necessary to carry out proper maintenance.

In this manual, unless otherwise explicitly indicated, the terms "stove", " "product" are used 

indistinctly to indicate our general device.

1.1 SAFETY WARNINGS

This installation, use and maintenance manual is an integral and essential part of the product and 

must be kept by the user.

Before proceeding with the installation, use and maintenance of the product, it is necessary to read 

it carefully. All local, national laws be met in the installation and use of the appliance.

The user is recommended to carry out all the maintenance operations indicated in this manual. 

This appliance must be intended only for the use for which it is intended. Any other use is to be 

considered improper and therefore dangerous; therefore any responsibility for improper use of the 

product will be borne by the user.

Installation, maintenance and any repairs must be carried out by professionally qualified personnel.

In case of repairs, only original spare parts supplied by the manufacturer must be used. 

Incorrect installation or poor maintenance can cause damage to people, animals or things; in this 

case the manufacturer will be relieved of any responsibility.

Before carrying out any cleaning or maintenance operations, turn off the appliance, using the main 

switch and disconnect the cable from the electric current.

It is necessary to install the product in suitable rooms and served by all services

(power supplies and drains) that the device requires for correct and safe operation.

We recommend that you take care of this manual and keep it.

The images and figures in this manual are purely illustrative.

Pasian also reserves the right to make changes at any time and without notice to the contents of 

this manual.

No liability will be accepted for damage, even to third parties, in the event that the instructions for 

installation, use and maintenance of the appliance are not followed. Modifications to the appliance 

made by the user or whoever is acting on his behalf must be considered as his  responsibility. The 

user is responsible for all the operations necessary to maintain the efficiency of the appliance.

Содержание Perla

Страница 1: ...Produzione stufe e termostufe a pellets e policombustibili User manual Perla CpPerla Luna Cp Luna Nina Cp Nina...

Страница 2: ...Model N serial number Dealer Purchase date In this space it is advisable to mark the data of the stove in this way you can always have a reference in case of request...

Страница 3: ...LCD CONTROL PANEL 5 DISPLAY 5 4 USER MENU 6 7 8 IINTRODUCTION 3 3 4 6 GENERAL DESCRIPTIONS 7 2 1 PACKAGING CONTENT 7 2 2 OPERETING WARNINGS 8 8 9 3 ASSEMBLY 1 3 1 AGENERAL WARNINGS 13 3 2 ELECTRICAL C...

Страница 4: ...improper use of the product will be borne by the user Installation maintenance and any repairs must be carried out by professionally qualified personnel In case of repairs only original spare parts s...

Страница 5: ...correct draft of the flue obstruction of the same or of the air intake pipe presence of residual material in the brazier that obstructs the holes alters the functioning of the stove which in the ignit...

Страница 6: ...he appliance are not followed Modifications to the appliance carried out by the user or whoever on his behalf the use of inappropriate fuels or without the necessary precautions must be considered as...

Страница 7: ...Kw Kg but with an advantageous purchase cost compared to traditional fossil fuels MAIS Corn is an ecological fuel renowned for its optimal thermal yield thanks to a lower level of humidity it is easy...

Страница 8: ...CIOLINO Deflector ash drawer electrical cable user manual ATTENTION the shape and aesthetic characteristics of the various components may undergo variations CARATTERISTICHE TECNICHE chimney 80 mm Nina...

Страница 9: ...al air exchange of an electrical connection that does not comply with the regulations and of inappropriate use of the stove The installation must be performed by a qualified technician who must issue...

Страница 10: ...which it is located this air must be reintegrated through an air intake outside the room itself The appliance is equipped with a socket to be able to take the combustion air directly from the outside...

Страница 11: ...ust be spaced from combustible or easily flammable materials with an air gap or insulating materials The use of flexible or extensible metal pipes or unsuitable material is not allowed Single or doubl...

Страница 12: ...ique for each generator no discharges in the flue shared with other devices are allowed figure 6 figura 7 If the smoke exhaust is inserted inside a pre existing flue this must be certified for solid f...

Страница 13: ...haust of fumes is ensured It must prevent the entry of rain snow and be without mechanical suction aids the chimney pot must be positioned in such a way as to exceed the ridge of the roof and must be...

Страница 14: ...VE FEATURES The filling compartment is located on the top The load capacity expressed in the technical data is to be considered variable according to the specific weight of the pellet When loading the...

Страница 15: ...er than the boiling point it is therefore necessary that the heating system is designed compatibly with the characteristics of the machine During installation and during operation keep in mind that th...

Страница 16: ...and to position in the case of assembly with closed vessel an automatic vent valve at the outlet of the thermo stove delivery pipe if the kit is not installed in the appliance ATTENTION IDRO boilers a...

Страница 17: ...INDICATIVE ASSEMBLY DIAGRAMS Classic connection diagram with radiators Connection diagram with heat exchanger for direct sanitary Hydro connection diagram with underfloor system...

Страница 18: ...nitary boiler Complete hydro connection diagram with solar panel P Circulator S Gate valve RIE Filling Valv Sfiato Vent valve P Circulator already in the boiler AQP Water ELE Electricity Mis Mixer Val...

Страница 19: ...r the thermostat is reset manually and must be done by pressing the buttons located on the back of the boiler and covered by screw on caps Info The intervention of the technical assistance center for...

Страница 20: ...user manual Motherboard Connections...

Страница 21: ...g 3 men access 4 start and stop 5 6 power increase decrease setting tasto 1 tasto 6 tasto 5 tasto 2 tasto 3 tasto 4 AIR FAN IN THE INTERNAL MODEL THERE IS AN AMBIENT FAN IT IS POSSIBLE TO ADJUST THE P...

Страница 22: ...e the auger is empty so loading the pellets will take several minutes 4 4 IGNITION AND NORMAL OPERATION Before proceeding with lighting the stove Check that the door is well closed Make sure that the...

Страница 23: ...asts about 5 minutes At the end of the stabilization phase FIRE PRESENT the stove passes to the normal working phase WORK As soon as the ignition phase is finished the stove goes into normal working m...

Страница 24: ...ues to operate at maximum speed for a minimum time of about 10 minutes to ensure complete cooling of the stove The hot air fan also continues to operate until the stove cools down and turns off ATTENT...

Страница 25: ...n the figure The contact to be used is of the NO type Normally open if there is no clean contact place a relay between the thermostat and the terminal board of the machine The connection of unsuitable...

Страница 26: ...CONSOLE...

Страница 27: ...28...

Страница 28: ...5 4 USER MENU...

Страница 29: ...USER MENU 09 Technical menu 10 Abilita combustibile 11 Tipo combustibile under key 1 2...

Страница 30: ...USER MENU...

Страница 31: ...USER MENU...

Страница 32: ...and so on up to PROGRAM 4 USER MENU...

Страница 33: ...USER MENU...

Страница 34: ...his parameter allows the selection between the 2 configurations in the memory Selection after activation 1 or 2 USER MENU usable only by technician under lock and key usable only by technician under l...

Страница 35: ...OFF START Operation mode To light the stove press button P4 for a few seconds Display changes the state of all Lighting the Boiler...

Страница 36: ...T TEMP MODIFY SET WATER TEMP Ignition failure At the end of the ignition phase the stove goes into the normal working mode Work time To change the temperature ambient please taste the P2 button and af...

Страница 37: ...ed Modulation of fan When the temperature of water reach the set value the boiler goes at minimum level This is a step by step phase and terminated itself into MODULATION PHASE Modulation of boiler Th...

Страница 38: ...o make the connection on the motherboard instead of the bridge 10 pole terminal block pin 3 4 Stove start when contact is closed free contact Connection and use of external thermostat If the ignition...

Страница 39: ...als and with a predetermined duration In this phase the fume extractor will increase the number of revolutions while the fuel drop will be reduced to a minimum to allow cleaning of the brazier and con...

Страница 40: ...For safety reasons re ignition of the stove will be possible when the fumes are cold and a pre established technical cooling time has elapsed OFF TIME RE START Re start Stop...

Страница 41: ...checks and will continue if the working conditions are valid in the state prior to the power failure as per the following diagram OPERATION STATE ALARM NO FIRE LACK OF ELECTRICITY in all other cases t...

Страница 42: ...s case the stove goes into stop Alarm sond fume This error occures when sond of fume is broken or dirty or there are a problem inside the motherbord Alarms If some problems can be appare in the stove...

Страница 43: ...tself the stop procedure ALARM STOP DURING WORKING TIME If during normal work of stove the flame turn off and the temperature of fume falls below a determinate threshold of work it s activated the ala...

Страница 44: ...Once a week or if there is a lot of residue clean the baffles Before re igniting the stove check that the brazier is inserted correctly and that the hole corresponds to the spark plug the pellet tank...

Страница 45: ...e residues of the 18 front tubes will fall into the compartment ash then remove any residues vacuuming everything the residues of the 4 largest pipes will fall into the ash collection compartment whic...

Страница 46: ...residues have accumulated inside the tank it is necessary to completely empty the tank and check that there are no residues that obstruct the normal operation of the auger It is also necessary to carr...

Страница 47: ...t the product cool down reset the thermostat until the lock goes out and turn the appliance back on if the problem persists contact technical assistance door open or seals worn Close the door and repl...

Страница 48: ...is weak Insufficient combustion air Make sure that the air intake in the room is present and free Clean the brazier and check that all the holes are clean Carry out a general cleaning of the combusti...

Страница 49: ...pump blocked Unblock the circulator Insufficient water temperature Wait for the temperature to reach 50 The sufa does not ignite Lack of electricity Check that the electrical outlet is plugged in and...

Страница 50: ...PR45 PR13 PR46 PR14 PR47 PR15 PR48 PR16 PR49 PR17 PR50 PR18 PR51 PR19 PR52 PR20 PR53 PR21 PR54 PR22 PR55 PR23 PR56 PR24 PR57 PR25 PR58 PR26 PR59 PR27 PR60 PR28 PR61 PR29 PR62 PR30 PR63 PR31 PR64 PR32...

Страница 51: ...____________________________________________________________ Eventuali ricambi_______________________________________________________ __________________________________________________________________...

Страница 52: ...____________________________________________________________ Eventuali ricambi_______________________________________________________ __________________________________________________________________...

Страница 53: ...non originali fa decadere la garanzia 7 Non previsto nessun indennizzo per il periodo di inefficienza della stufa o termostufa in attesa di riparazione 8 La garanzia personale e non cedibile a terzi 9...

Страница 54: ...po aver constatato che l installazione stata effettuata in accordo alle normative vigenti certifica di aver effettuato la prima accensione verificando il regolare funzionamento della stufa Il cliente...

Страница 55: ...CERTIFICAZIONE AMBIENTALE 4 STELLE...

Страница 56: ...MANUALE UTENTE USO E MANUTENZIONE PASIAN SRL SOGLIANO CAVOUR LE Tel Whatsapp 0836 543750 Fax 0836 544431 www pasianpellets it info pasianpellets it info pasian eu...

Отзывы: