N. B. The connection with several thermostats (ie multizone) must be made
through a clean contact relay.
The machine will restart when the water temperature has dropped below the set
temperature considering a cooling coefficient (about 5 degrees)
EXTERNAL
THERMOSTAT
RE-START
AFTER STOP
TO WATER
stand _ by
If you want to connect an external thermostat (room
thermostat), you need to make the connection on the
motherboard (instead of the bridge) - 10-pole terminal block
pin 3 / 4-
Stove start when contact is closed ( free contact)
Connection and use of external thermostat
If the ignition does not take place within a reasonable time, the
machine will report the Failed Ignition error.
Check everything and start again
Restart after stop due to Water temperature
If the dcause of stop is the external thermostat the stove restart after ok of this.
When the temperature exceeds the set temperature for a certain
time, the machine will enter the cooling waiting phase.
Содержание Perla
Страница 20: ...user manual Motherboard Connections...
Страница 26: ...CONSOLE...
Страница 27: ...28...
Страница 28: ...5 4 USER MENU...
Страница 29: ...USER MENU 09 Technical menu 10 Abilita combustibile 11 Tipo combustibile under key 1 2...
Страница 30: ...USER MENU...
Страница 31: ...USER MENU...
Страница 32: ...and so on up to PROGRAM 4 USER MENU...
Страница 33: ...USER MENU...
Страница 55: ...CERTIFICAZIONE AMBIENTALE 4 STELLE...