MANUALE UTENTE
,
USO E MANUTENZIONE
ANOMALIA
POSSIBILI CAUSE
RIMEDI
Failure to stop the
air fan.
air fan faulty
Wait a few minutes and check
engine operation and
Defective or faulty ambient
temperature probe.
Check the operation of the probe
and replace it if necessary.
the boiler has not yet reached the
switch-off temperature.
wait
.
Faulty electronic board
check or change
The boiler does not
circulate water
pump disconnected
check
pump blocked
Unblock the circulator
Insufficient water temperature
Wait for the temperature to reach
50 °
The sufa does
not ignite
Lack of electricity.
Check that the electrical outlet is
plugged in and that the system is
functioning
Smoke probe in block
check or replace probe
Fuse tripped following a fault
replace
Clogged exhaust or smoke duct
Clean the smoke outlet and /
or the smoke duct.
Badly positioned brazier
Check and reposition the burner
correctly in its seat.
electrical resistance faulty
check and replace resistance
Water temperature
does not rise
Dirty boiler
periodic maintenance
Power set too low
Increase the power
Содержание Perla
Страница 20: ...user manual Motherboard Connections...
Страница 26: ...CONSOLE...
Страница 27: ...28...
Страница 28: ...5 4 USER MENU...
Страница 29: ...USER MENU 09 Technical menu 10 Abilita combustibile 11 Tipo combustibile under key 1 2...
Страница 30: ...USER MENU...
Страница 31: ...USER MENU...
Страница 32: ...and so on up to PROGRAM 4 USER MENU...
Страница 33: ...USER MENU...
Страница 55: ...CERTIFICAZIONE AMBIENTALE 4 STELLE...