Attention
It is forbidden to use nets and other devices that can obstruct the end of the flue
(including caps for gas boilers) and to use "T" (figure 8) or "H" (figure 9) shaped
terminals or open caps (figure 10).
In the event that the mouth of the
existing flue is not perpendicular to the
smoke outlet of the hearth, their
connection must be made using the
appropriate inclined fitting
(figure 7).
figura 6
f
igura 8
figura 9
figura 10
The exhaust system must be unique for each generator, no discharges in the flue
shared with other devices are allowed (figure 6).
(
figura 7
If the smoke exhaust is inserted inside a pre-existing flue, this must be certified for solid
fuels, be kept in optimal conditions and appropriately insulated.
An external flue pipe can only be used if it meets the following requirements:
Only insulated (double-walled) stainless steel pipes fixed to the wall should be used for the
ductsat the end of the duct there must be an inspection to perform periodic checks and
maintenance.The duct must be equipped with a windproof chimney and respect the
distances from the ridgeof the building (figure 11).