background image

Only dispose off in authorised sites for electrical and electronic waste do not dispose of with general refuse or landfill waste.

www.parweld.com

19

9.2 Weee Statement

WEEE (Waste Electrical & Electronic Equipment) 2002/96/EC
 
In relation to implementing the legislation, Parweld has established relevant recycling and recovery methods.  We have been fully compliant 

against the marking requirements since August 2005. Parweld is registered in the UK with the Environment agency as detailed below.  For 

WEE compliance outside the UK please contact your supplier/Importer

Parweld is registered with a compliance scheme Official registration number is WEE/FD0255QV

When your equipment reaches the end of its service life you should return it to Parweld where it will be reconditioned or processed for 

recycling.

9.3 Statement of warranty

Limited Warranty: 
Parweld Ltd, hereafter, “Parweld” warrants its customers that its products will be free of defects in workmanship or material. Should any failure 

to conform to this warranty appear within the time period applicable to the Parweld products as stated below, Parweld shall, upon notification 

thereof and substantiation that the product has been stored, installed, operated, and maintained in accordance with Parweld’s specifications, 

instructions, recommendations and recognized standard industry practice, and not subject to misuse, repair, neglect, alteration, or accident, 

correct such defects by suitable repair or replacement, at Parweld’s sole option, of any components or parts of the product determined by 

Parweld to be defective.

Parweld makes no other warranty, express or implied. This warranty is exclusive and in lieu of all others, including, but not limited to any 

warranty of merchantability or fitness for any particular purpose.

Limitation of Liability: 

Parweld shall not under any circumstances be liable for special, indirect or consequential damages, such as, but not limited to, lost profits and 

business interruption. The remedies of the purchaser set forth herein are exclusive and the liability of Parweld with respect to any contract, or 

anything done in connection therewith such as the performance or breach thereof, or from the manufacture, sale, delivery, resale, or use of any 

goods covered by or furnished by Parweld whether arising out of contract, negligence, strict tort, or under any warranty, or otherwise, shall not, 

except as expressly provided herein, exceed the price of the goods upon which such liability is based. No employee, agent, or representative 

of Parweld is authorized to change this warranty in any way or grant any other warranty.

Purchaser’s rights under this warranty are void if replacement parts or accessories are used which in Parweld’s sole judgement may impair the 

safety or performance of any Parweld product.

Purchaser’s rights under this warranty are void if the product is sold to purchaser by non-authorized persons.

The warranty is effective for the time stated below beginning on the date that the authorized Distributor delivers the products to the purchaser. 

Notwithstanding the foregoing, in no event shall the warranty period extend more than the time stated plus one month from the date Parweld 

delivered the product to the authorized distributor.

Main Transformers and Rectifiers 2 Years

Other machine parts 2 year

Содержание XTM254i

Страница 1: ...Operator Manual ISSUE 2 XTM254i...

Страница 2: ...er maintanance this equipment should provide years of reliable service All our systems conform to ISO9001 2000 and are independently audited by NQA The entire product range carries the CE mark and is...

Страница 3: ...Connections 7 5 5 Changing drive roll sets 7 5 6 Welding wire installation 7 5 7 torch installation 7 5 8 Work return lead connection 8 5 9 Shielding gas connection 8 6 0 Operation 8 6 1 Feeding wire...

Страница 4: ...manual Wear a safety harness if working above floor level Keep all panels and covers securely in place Clamp work cable with good metal to metal contact to work piece or worktable as near the weld as...

Страница 5: ...ect pacemakers Pacemaker wearers keep away Wearers should consult their doctor before going near arc welding gouging or spot welding operations NOISE can damage hearing Noise from some processes or eq...

Страница 6: ...LEFT ADJUST KNOB Its main function is adjusting welding current in synergic mode and the wire speed in manual mode 6 VOLTAGE DISPLAY INDICATOR It will be display Arc Force preset in MMA and display vo...

Страница 7: ...y for MIG welding with GAS 5 5 Changing drive roll sets 1 Turn off the power source 2 Release the pressure on the idle roll by swinging the adjustable pressure arm down toward the back of the machine...

Страница 8: ...blue hose The blue hose delivers cold water directly to the prime source of heat the swan neck and consumable The re circulated water is then passed through the torch power cable to cool the power ca...

Страница 9: ...lding release the gun trigger and then pull the gun away from the work after the arc goes out 5 When no more welding is to be done close valve on gas cylinder if used momentarily operate gun trigger t...

Страница 10: ...ts are made to weld it Trouble may also be experienced when welding white heart malleable due to the porosity caused by gas held in this type of iron Copper and alloys The most important factor is the...

Страница 11: ...nless steel 318l 16 high corrosion resistance Ideal for dairy work etc On stainless steels TIG Welding guide Using the selector button 8 toggle through the functions until the MMA light is illuminated...

Страница 12: ...weld metal melting Completely through base metal Resulting in holes where no metal remains Excessive heat input Select lower voltage range and reduce wire feed speed Increase and or maintain steady tr...

Страница 13: ...or wire guide junctions Incorrect contact tip size Contact Tip overheating Spatter adhesion on exit geometry of tip bore Excessive cable kinkage Poor earth or cable connections Weld joint area dirty Y...

Страница 14: ...XP2024 12 40 Steel Liner 0409 0459 1 0mm 1 2mm x 13ft 4m XP2024 12 50 Steel Liner 0409 0459 1 0mm 1 2mm x 16ft 5m NI XP2024PC 12 30 Polyamide Copper Liner 0309 0459 0 8 1 2mm x 10ft3m XP2024PC 12 40 P...

Страница 15: ...pm flow E700123 2 Gauge Argon 30 lpm flow Flow Meters Features Designed from brass bar whilst the tube and cover are moulded from high quality polycarbonate to ensure high impact resistance and clarit...

Страница 16: ...0 5 Amps 90 105 11 140 Volts 14 7 14 9 15 9 17 Amps 62 100 125 155 Volts 13 5 17 19 5 20 3 Amps 80 110 130 140 Volts 14 17 19 5 20 3 Amps 80 110 130 140 Volts 14 17 19 5 20 3 Amps 62 83 100 120 Volts...

Страница 17: ...0 6 9 20 22 1 22 5 23 5 23 5 30 160 180 200 215 225 6 9 20 5 21 1 22 5 23 5 23 9 30 160 180 200 220 240 6 9 20 5 21 1 22 5 23 5 24 1 11 140 146 166 180 200 5 9 17 17 9 19 3 21 5 23 5 25 155 170 200 18...

Страница 18: ...to be compliant with the rohs directive with all homogeneous component parts being controlled to ensure material contents as per the list below Cadmium 0 01 by weight Lead 0 1 by weight Mercury 0 1 by...

Страница 19: ...ld to be defective Parweld makes no other warranty express or implied This warranty is exclusive and in lieu of all others including but not limited to any warranty of merchantability or fitness for a...

Страница 20: ...Parweld Limited Bewdley Business Park Long Bank Bewdley Worcestershire England DY12 2TZ tel 44 1299 266800 fax 44 1299 266900 www parweld com info parweld co uk...

Отзывы: