www.parweld.com
24. TROUBLESHOOTING
Below are a list of some of the most common problems that may arise, with the relative
solutions.
DEFECT
CAUSE
SOLUTION
Machine switches off
[display: off]
[display: network error]
Lack of tension on the supply
grid.
Refresh the power supply
tension.
Check supply grid.
Refresh the power supply
tension.
The machine suddenly stops
working after prolonged use
[display: overheating or
inverter
overload]
The machine has overheated
due
to excessive use and the
thermal
protection has intervened.
Leave the machine to cool until the
warning message disappears
[display: inverter under-
voltage]
MMA: electrode in contact
with the
earth.
MMA: electrode in contact with
the earth.
Arc off
Poor contact between the
earth
clamp and the workpiece.
Tighten the clamp and check
again.
Short circuit between the
contact
nozzle and the gas tube.
Clean and replace contact
nozzle and wire-feeder tip.
Porous welding seam
Gas shield absent due to
build-up
of deposits in the gas nozzle.
Clean any eventual deposits.
Incorrect tilt angle of torch.
The distance between the torch
and the workpiece must be
5-10mm; the tilt angle must be
no less than 60 degrees from
the workpiece.
Not enough gas
Increase gas
Damp workpiece
Dry with a hot air pistol or other
means.
Welding arc is too long
Shorten the arc
Scarce fusion
fast torch movements
Slow down torch movement
Rusty material
Clean
Lateral incisions
Welding speed is too high
Reduce welding speed
[display: no SD-card]
The SD-card has been
removed
Insert SD-card
24
Содержание DP323C
Страница 1: ...ISSUE 2 User Manual DP323C...
Страница 3: ...CONTENTS 2...
Страница 4: ...www parweld com 3...
Страница 5: ...www parweld com 4...
Страница 6: ...www parweld com 5...
Страница 9: ...www parweld com 8 3 LOADING THE WELDING WIRE To load the welding wire follow these instructions...
Страница 24: ...www parweld com 23...
Страница 26: ...www parweld com 25...