Settings that do not appear on the screen are
accessible by turning switch 10.
Once the type of wire has been selected (using switch
10), the settings page for the welding wire diameter will
appear.
Arc length: This changes the length of the electric weld
arc with respect to the pre-set synergic values.
Deposit: This modifies the deposit of the filler material
(velocity of the wire) with respect to the pre-set
synergic values.
Inductance: This changes the variation speed of the
welding current to achieve a sharper (low values) or
softer arc (high values).
Double short: This activates (ON) or deactivates (OFF)
the two level option, i.e. the continuous switching
between two different welding tension levels.
L1 span: When the two level mode is active the
duration of the first power level can be set.
L2 span: When the two level mode is active the
duration of the second power level can be set.
L2 amplitude: When the two level mode is active the
second power level (L2) can be set with respect to the
set power (level L1).
2t-4t-4bilevel: This function adjusts the 2 step or 4 step
settings.
2t: In 2 step mode, the machine will weld for as long as
the torch trigger is pressed down.
4t: : In 4 step mode, press the trigger once to start the
torch, press again to stop the torch.
4Bi: In 4 step Bi- Level mode, press the trigger once to
start the torch, successively, briefly pressing the trigger
(for less than 1s) will cause the set welding current
to pass to second level and vice versa. Prolonged
pressure on the torch trigger will halt the welding
process.
2nd level: This option is for setting the values the wire
speed, corresponding to the second power level, which
is active when the values of the 2t-4t-4bi-level is set to
4bi.
Initial/final current: it allows to switch up (ON) or down
(OFF) mode with starting/final current.
Initial current: allows setting the value at which the
welding current is brought to immediately after the
striking of the electric arc
Initial time: allows setting the time of the current
established by the Initial Current parameter. In 4t/4bi
mode this time is irrelevant and the initial current is
kept for as long as the torch button is held down.
Ramp ls- > l1: allows setting the duration of the
upslope of the welding current.
Ramp l1- > lf: allows setting the duration of the
downslope of the welding current
Final current: allows setting the value at which the
welding current is brought to on completion of the
downslope
Final time: allows setting the time of the current
established by the Final Current parameter. In 4t/4bi
mode, this time is irrelevant and the final current is
kept for as long as the torch button is held down.
Spot welding: This sets the maximum welding duration
(when different to 0), in seconds.
Pause: This sets the duration of the pauses (when
different to 0), between two successive tacks.
Pre gas time: This sets the gas supply time before the
welding current is supplied.
Post gas time: This sets the gas supply time after the
welding current supply ends.
Содержание DP323C
Страница 1: ...ISSUE 2 User Manual DP323C...
Страница 3: ...CONTENTS 2...
Страница 4: ...www parweld com 3...
Страница 5: ...www parweld com 4...
Страница 6: ...www parweld com 5...
Страница 9: ...www parweld com 8 3 LOADING THE WELDING WIRE To load the welding wire follow these instructions...
Страница 24: ...www parweld com 23...
Страница 26: ...www parweld com 25...
Страница 27: ...www parweld com 26 Spare Parts 26...