P
AGE
58
(Continued from page 57)
Relay A
R12
Terminal C
Relay B
R13 Terminal E
Relay C
R14 Terminal G
Return the instrument to the case and tighten the front
panel screw. Turn the power on to the instrument and
check the operation of the output(s).
mADC Output(s)
1. Verify that the Program and Tune mode parameters
Malfunction
are correctly set (page 25 & 32 or the Software Ref.
Sheet, page 75, if already filled out).
2. Turn off the power to the instrument. Wait about 5
seconds and turn the power on again. Confirm that
the model number displayed during the power up
sequence indicates that the output is present in the
instrument. The number should match the model
number on the label located on the bottom of the
front display bezel. If the model # is incorrect, follow
the steps for "Model # displayed is incorrect" (page
57).
3. Verify that the hardware is present on the Option
board (Appendix A-3, page 65 or 66).
4. Check the output operation in the Test mode. Use
Test 7 for Output 1 and Test 8 for Output 2. If the
output works in the Test mode, re-check the Program
& Tune mode parameter settings ( pages 25 - 32,
or the Software Ref. Sheet, page 75, if already filled
out).
Error Code Displayed
SnSr
1. Inspect the sensor for proper operation and
Sensor Break or out of range
connection to the instrument. Acceptable sensor
ranges for the instrument are listed in the
Specifications section of Appendix D (page 71).
2. Verify that the Program mode input selection matches
the sensor input connected.
3. Check that the input conditioning jumpers on the
Processor board (Appendix A-2, page 64) and the
Option Board (Appendix A-3, page 65 or 66) are in the
proper position for the sensor input.
4. Perform the calibration procedure(s), as described in
the Calibration section (page 47) for the sensor input
type.
FbEr
1. Inspect the Slidewire Feedback connections at
Slidewire Feedback Error
terminals 8, 7 and 5. Be sure that the connections are
the same as shown in the position proportioning
illustration (page 20).
Содержание MIC 6000
Страница 1: ...Form 2854 Edition 10 December 1993 Installation Wiring Operation Manual MIC 6000 Brand ...
Страница 27: ...PAGE 27 PiA rrH PFF dFF Co1r Ptb Co2r Pout Pou PoL CCon CbS C C B Com Optional EO Option CAd ...
Страница 82: ...THE PARTLOW WEST COMPANY 2 CAMPION ROAD NEW HARTFORD NY 13413 USA 1 800 866 6659 315 797 2222 FAX 315 797 0403 ...