P
AGE
25
Operation Summary 3.5
The configuration and operating modes, the method of moving from one mode to another,
and the basic parameter functions are described in each individual section . Data and
parameter entry is made by stepping through each mode and making an appropriate
response or entry to each step.
3.5.1 MODE SELECTION
If the instrument is in either the Off mode or Control mode, repeated depression of the Scroll
key will cause the instrument to display the code corresponding to each mode which is
enabled and each profile which has been entered. To enter a mode while its code is
displayed, depress the Down key.
To exit the OFF mode, press the SCROLL key until CtrL is displayed, then press the DOWN
key.
Entry into any mode except the Control, Tune, Standby, Enable and Profile execution, will
cause the instrument's outputs to turn off. Access to the Tune mode is provided while the
instrument continues normal operation if in Control or running a Profile.
3.5.2 CONFIGURATION DISPLAYS
During configuration, the display is used to show the parameter codes and values. During
normal operation, these displays are used to indicate process values, setpoints, etc. .
TABLE 3-1 PROGRAM MODE CONFIGURATION PROCEDURE
Press and release the SCROLL key until Prog is displayed. Press the DOWN key to enter
the Program mode. Press the SCROLL key to advance the display through the parameter
codes and their values. Use the Up and DOWN keys to adjust the values. After adjusting a
parameter, press the SCROLL key to proceed to the next parameter. Each time the DOWN
key is pressed while a parameter code is being displayed, such as dFF, the next parameter
code in the sequence will be displayed.
After all selections have been made, to exit the mode, press the UP key with a parameter in
the display (not a setting ).
For illustration purposes, all available Program mode parameters have been listed. The
parameters that will appear on the specific instrument will depend upon the model number
(hardware configuration) of the instrument and on the parameter selections previously made.
For future reference, record the parameter selections for the application in the "Your Setting"
column and on the Software Reference Sheet in Appendix E (page 75).
To prevent unauthorized changes to the Program mode, the mode can be disabled (turn off)
in the Enable mode.