All-in-one solar charge inverter V11 38
8.
Technical parameters
Models
HF4830S60 -145
HF4840S80 -145
HF4850S80-145
AC mode
Rated input voltage
220/230Vac
Input voltage range
(170Vac~280Vac) ±2%/(90Vac-280Vac) ±2%
Frequency
50Hz/ 60Hz (Auto detection)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit
protection
Circuit breaker
Efficiency
>95%
Conversion time
(bypass and inverter)
10ms (typical)
AC reverse protection
Available
Maximum bypass overload
current
30A
40A
Inverter mode
Output voltage waveform
Pure sine wave
Rated output power (VA)
3000
4000
5000
Rated output power (W)
3000
4000
5000
Power factor
1
Rated output voltage (Vac)
230Vac
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz/60Hz ± 0.3Hz
Maximum Efficiency
>92%
Overload protection
(102% < load <125%) ±10%: report error and turn off the output after 5 minutes;
(125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds;
Load >150% ±10%: report error and turn off the output after 5 seconds;
Peak power
6000VA
8000VA
10000VA
Loaded motor capability
2HP
3HP
4HP
Rated battery input voltage
48V (Minimum starting voltage 44V)
Battery voltage range
Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery...
settable on LCD screen)
Power saving mode self-
consumption
Load≤50W
AC charging
Battery type
Lead acid or lithium battery