All-in-one solar charge inverter V11 26
Parameter
no.
Parameter
name
Settings
Description
06
Charger source
priority
[06] CSO
PV priority charging; only when the PV charging fails,
the mains charging is started.
[06] CUB
Mains priority charging; only when the mains
charging fails, the PV charging is started.
[06] SNU
default
PV and Mains hybrid charging; PV charging is a
priority, and when the PV energy is insufficient, the
Mains charging supplements. When the PV energy is
sufficient, the Mains charging stops. Note: Only when
the Mains bypass output is loaded, the PV charging
and the mains charging can work at the same time.
When the inverter works, only the PV charging can be
started.
[06] OSO
Only PV charging, with the Mains charging not
activated.
07
Max charger
current
[07] 80A
default
230Vac Max charger current (AC PV charger).
Setting range: 0~140A;
HF4830S60-145
Max charger current (AC
PV charger). Setting range: 0~120A;
08
Battery Type
[08] USE
User-defined; all battery parameters can be set.
[08] SLd
Sealed lead-acid battery; constant-voltage charge
voltage: 57.6V, floating charge voltage: 55.2V.
[08] FLd
Vented lead-acid battery; constant-voltage charge
voltage: 58.4V, floating charge voltage: 55.2V.
[08] GEL
default
Colloidal lead-acid battery; constant-voltage charge
voltage: 56.8V, floating charge voltage: 55.2V.
[08]
LF14/LF15/LF16
Lithium iron phosphate battery LF14/LF15/LF16,
corresponding to 14strings ,15 strings and 16 strings
of lithium iron phosphate battery; for 16 strings,
default constant-voltage charge voltage is 56.8V; for
15 strings, default constant-voltage charge voltage is
53.2V; for 14 strings, default constant-voltage charge
voltage is 49.2V; allow adjustable.
[08] N13/N14
Ternary lithium battery; which is adjustable.
09
Battery boost
charge voltage
[09] 57.6V
default
Boost charge voltage setting; the setting range is
48V~58.4V, with step of 0.4V; it is valid for user-
defined battery and lithium battery.