40
GB
24. Emission levels are represented in the technical
data under the stated values for sound power
level (LWA) and sound pressure level (LpA) and
are not compulsory definite working levels.Be
-
cause there is a connection between emission
levels and immission levels, this can not reliably
used to determine the potentially necessary
additional precautions. Influencing factors on
the workforce‘s current immission level includes
the properties of the work area, other noise
sources, air borne sound, etc. such as e.g. the
number of machines and other neighbouring
processes and intervals, to which the user is
exposed. Also the admissible immission levels
can vary from country to country. However,
this information gives the user of the machine
the opportunity to have a better estimation of
the risks and dangers. Occasionally acoustic
measurements should be take after installation
in order to determine the sound pressure level.
ATTENTION: Only use unleaded normal
petrol as fuel.
6. Before operation
Installation
(Fig. 1/2)
To attach the handle (1), remove both Phillips screws
M6x35 mm which are inserted. Place the handle (1)
in position and screw it tight. Attach all parts before
pouring in fuel or oil in order to prevent leaking of
liquids.
Electrical safety
Electrical cables and attached devices must be de-
fect free. Never connect the generator to the mains
(power point). Keep the cables as short as possible.
Environmental protection
Dispense of polluted maintenance and operating
materials in a suitable collection point.
Earthing
(Fig. 1)
Earthing is needed to disperse static discharge.
Connect a cable from one side of the earthing con-
nector (7) of the generator and from the other side to
an external ground.
ATTENTION!
When being used for the first time,
motor oil (15 W-40, approx. 0.25 l) and petrol (un-
leaded normal petrol) must be put in.
Check the fuel level and the oil, and if necessary top
them up. Make sure you have adequate ventilation.
Ensure that the spark cable is securely in the spark
plug. Unplug any electric device connected to the
generator.
Putting in oil (Fig. 5)
Put the generator with its front side down and
unscrew the oil filler plug (13). Pour in 0.25 litres of
engine oil (15 W-40).
Acceptable ambient temperature:
-10 to +40 °C
Height:
1000 m above NN
rel. air humidity:
90 % (not condensed)
5. Safety instructions
1.
No modifications are allowed to be made to the
generator
2. The speed preset by the manufacturer may
not be changed. The generator or connected
devices could be damaged.
3.
Risk of poisoning!
Fumes, fuels and lubricants
are toxic. Do not breath in the fumes.
4.
Fire risk!
Petrol and petrol fumes are highly
flammable and explosive.
5. Do not use the generator in non ventilated
rooms or in highly flammable areas. When the
generator should be used in a well ventilated
room, the fumes must be channeled outside
through a exhaust hose.
6. Even when using an exhaust hose, toxic gas
can still escape. Due to the risk of fire, the
exhaust hose should never be aimed at com-
bustible material.
7. Never use the generator in rooms with highly
flammable materials.
8.
Hot surface!
Risk of burning, do not touch the
exhaust system and engine unit.
9. Do not touch any of the mechanically moving or
hot parts. Do not remove any of the protective
caps.
10.
Protective equipment!
Use suitable ear pro-
tection when near the device.
11. Only original parts should be used for mainte-
nance and accessories.
12. Repair and maintenance work must only be
performed by authorised qualified personnel.
13. Protect yourself from electric shocks.
14. Never touch the generator with wet hands
15. Only use outside with a extension cable which
is suitable for that and is appropriately marked
(H07RN).
16. When using an extension cable, the total length
should not exceed 50 m for 1.5 mm², 100 m for
2.5 mm².
17. Do not use the generator in the rain or snow.
18. Always turn off the engine when transporting or
refuelling.
19. Ensure that no fuel is spilt on the engine or
exhaust when refuelling.
20. Do not refuel or empty near naked lights or
flames or flying sparks. Do not smoke!
21. Put the generator on a secure and level place.
Turning, tipping or changing its position during
operation is forbidden.
22. Install the generator at least 1 m away from the
walls or attached devices.
23. Keep the generator away from children.