“B” Series
“B” Series
“F” Series
“Solstar” Series “Solstar” Series
Voltage
Standard
“02” Option
“H Series”
“NC” Solenoid
“NO” Solenoid
Pins Up
Pins Down
Pins Down
Pins Down
Pins Down
12VAC
—
—
—
—
—
24VAC
PS2982*42P
†
PS3541*42P
†
PS3541*42P
PS3541*42P
†
PS3201*42P
†
120VAC
PS2982*53P
PS3541*53P
PS3541*53P
PS3541*53P
†
PS3201*53P
†
240VAC
PS2982*57P
†
PS3441*57P
†
PS3441*57P
—
—
12VDC
PS2982*45P
†
PS3541*45P
†
PS3541*45P
PS3541*45P
†
PS3201*45P
†
12VDC** PS2982*47P
††
—
—
—
—
24VDC
PS2982*49P
PS3541*49P
PS3541*49P
PS3541*49P
†
PS3201*49P
†
24VDC** PS2982*48P
††
—
—
—
—
48VDC
—
—
—
PS3541*51P
†
PS3201*51P
†
“Interface 2000”
“15mm Solenoid”
“15mm Solenoid”
“15mm Solenoid”
Voltage
& “PVL” Series
“NO” Series
“NC” Series
“NC” Series
Pins Down
Pins Up
Pins Down
Pins Up
12VAC
—
—
—
—
24VAC
PS3441*42P
†
PS3202*42P
§
PS3541*42P
†
PS2982*42P
†
120VAC
PS3441*53P
†
PS3202*53P
§
PS3541*53P
PS2982*53P
‡
240VAC
—
—
PS3441*57P
†
PS2982*57P
†
12VDC
PS3441*45P
†
PS3202*45P
§
PS3541*45P
†
PS2982*45P
‡
12VDC**
—
—
—
PS2982*47P
§§
24VDC
PS3441*49P
†
PS3202*49P
§
PS3541*49P
PS2982*49P
‡
24VDC**
—
—
—
PS2982*48P
§§
48VDC
PS3441*51P
†
—
—
—
* = Override Option
B = Flush, Non-Locking
C = Flush, Locking
D = Extended, Non-Locking
E = Extended, Locking
** = Mobile Voltage
†
= Not available with Override Options D and E.
††
= Not available with Override Options B and C.
‡
= Not available with Override Option E.
§
= Only available with Override Option B.
§§
= Only available with Override Option D.
Service Instructions:
V402EP
15mm Solenoid Replacement Kits
ISSUED: September, 2006
Supersedes: January, 2004
Doc. #V-402P, ECN #060870, Rev. 7
Replacement of 15mm Solenoid Assembly
Introduction
Follow these instructions when replacing a solenoid pilot valve
assembly on B, F, H, Solstar, Interface 2000, and PVL Series and
on individual manifold and subbase mounting solenoids.
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Operating Inlet Pressure:
kPa
psig
bar
Max.
(2 & 3-Position)
1000
145
10.0
NOTE:
Solenoid operated valves, when specified with external pilot, may
have operating pressures down to vacuum in the main valve. External pilot
pressure and air pilot signals must be greater than or equal to that in the
main valve, but not outside the ratings above.
Normal Ambient Temperature Range:
-15°C to 49°C
(5°F to 120°F)
Mobile Ambient Temperature Range:
-40°C to 70°C
(-40°F to 158°F)
Normal Voltage Range:
Rated V10%, -15%
Mobile Voltage Range:
Rated V25%, -30%
Wiring
Follow all requirements for local and national electrical codes.
Pneumatic Division
Richland, Michigan 49083
Service Kits Available
The following service kits contain the appropriate seals and parts
necessary for ordinary field service.
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to this
product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered by
paint, etc. If masking is not possible, contact your local representative
for replacement labels.
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its
subsidiaries and authorized distributors provide product and/or system options
for further investigation by users having technical expertise. It is important
that you analyze all aspects of your application, including consequences of
any failure and review the information concerning the product or systems
in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own
analysis and testing, is solely responsible for making the final selection of the
products and systems and assuring that all performance, safety and warning
requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by Parker
Hannifin Corporation and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
!
Safety Guide
For more complete information on recommended application
guidelines, see the Safety Guide section of Pneumatic Division
catalogs or you can download the
Pneumatic Division Safety
Guide
at: www.parker.com/safety