Installation Instructions: Form V-438CP
F3 / F5 Series Valves - Manifold with
Flexboard - Option D & E
ISSUED: May, 2000
Supersedes: Oct, 1999
ECN# P27661
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS
AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE
DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you analyze all
aspects of your application, including consequences of any failure and review the
information concerning the product or system in the current product catalog. Due to
the variety of operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making the final
selection of the products and systems and assuring that all performance, safety and
warning requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by Parker
Hannifin Corporation and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN
EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
Pneumatic Division North America
Richland, Michigan 49083
Pneumatic
!
WARNING
To avoid unpredictable system behavior that can cause personal
injury and property damage:
• Disconnect electrical supply (when necessary) before
installation, servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected
to this product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure,
temperature, and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must
be performed by knowledgeable personnel who understand
how pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the
product tested for proper function and leakage. If audible
leakage is present, or the product does not operate properly,
do not put into use.
• Warnings and specifications on the product should not be
covered by paint, etc. If masking is not possible, contact your
local representative for replacement labels.
Introduction
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed air systems only. Compliance with the rated
pressure, temperature, and voltage is necessary - see Installation
& Operating Instructions (V-430CP) packed with valve.
Operating Pressure Range:
kPa
psig
bar
Min. (2-Position - Air Return) 140
20
1.4
Min. (2-Position w/Spring
and Air Return)
240
35
2.4
Min. (3-Position)
210
30
2.1
Max. (2 & 3-Position)
996
145
10.0
NOTE: Solenoid operated valves, when specified with external
pilot, may have operating pressures down to vacuum in
the main valve. External pilot pressure and air pilot
signals must be greater than or equal to that in the
main valve, but not outside the ratings above.
Ambient Temperature Range: -15°C to 49°C (5°F to 120°F)
Voltage Range: Rated V10%, -15%
!
CAUTION: An interruption of 10 milliseconds or greater
to the power supplied to the solenoid of a solenoid
operated valve may cause the valve to shift. Provision
must be made to prevent power interruption of this
duration to avoid unintended, potentially hazardous,
consequences.
Current (Amp) Limits
•
Common Pin (13) rated for 3 amp maximum.
Maximum Solenoids Energized Simultaneously
25-Pin Sub-D
Serial Bus
12VDC
18
—
24VAC
22
—
24VDC
24
32
120VAC
24
32
(F3 Shown)