background image

4

SMOG-HOG Electrostatic Precipitator    PCN Series

2. Installation

2.1 Packaging 

The Smog-Hog PCN is shipped in three containers. One consists of the main cabinet and operating 
components. The second is the factory-assembled extraction arm with duct in place. The third is the hood. 
 

2.2 Inspection Note

Upon receipt of your unit, check for any shipping damage. A damaged carton indicates that the 
equipment may have received rough handling during shipping that may have caused possible  
internal damage. Notify your delivery carrier and enter a claim if any damage is found.  

2.3  Installing the Extraction Arm Assembly 

The top of the PCN cabinet has eight 3/8-16 threaded inserts in the cabinet, and equally spaced 
around the air entry opening. The mating extraction arm mounting flange is ready for installation, and 
the mounting hardware (bolts, flat washers, and split ring lock washers) is in a plastic bag inside the 
main cabinet. The extraction arm assembly is approximately 50 lbs, but because of its size, may be 
best positioned by two people. The extraction arm support spring is in place on the assembly, with a 
protective shipping retainer box strapped in place (these must be removed before operating the unit). 
All pivot points are tightened slightly to keep arms from moving during handling. This assembly is 
shipped for installation so that the arm nearest the cabinet is in the vertical position when the bearing 
flange is being bolted down. With this arm extending up from the top of the cabinet, a ceiling height 
of about 10´ is required for adequate clearance. Refer to the SA Installation and Owner’s Manual for 
instructions on assembling the extraction arm or making field adjustments. 

!

 

  C A U T I O N

Sharp pulls on the arm or hood should be avoided since damage to the arm components could result.

Содержание Smog-Hog PCN

Страница 1: ...Smog Hog Portable Electrostatic Precipitator Owner s Manual Model PCN...

Страница 2: ...r service have the following information available when contacting Parker Unit Order ___________________________________________________________________ Unit Model ____________________________________...

Страница 3: ...Unit On 3 3 2 Operating the Unit 3 4 Maintenance and Cleaning 4 4 1 Cleaning Schedules 4 4 2 Component Cleaning 4 4 3 Periodic Maintenance 5 4 4 Other Maintenance 5 5 Troubleshooting Guide 6 5 1 How t...

Страница 4: ...om unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage Operate only in a safe and serviceable conditio...

Страница 5: ...of Parker Parker disclaims any liability or responsibility for damage from fires or explosions regardless of origin Parker recommends that all APC dust collection equipment installation and applicati...

Страница 6: ...SMOG HOG Electrostatic Precipitator PCN Series Page intentionally left blank...

Страница 7: ...n attract the particles Air next passes through a centrifugal blower where it is exhausted vertically through an adjustable outlet grille back to the work space An integrally mounted power pack conver...

Страница 8: ...llation and the mounting hardware bolts flat washers and split ring lock washers is in a plastic bag inside the main cabinet The extraction arm assembly is approximately 50 lbs but because of its size...

Страница 9: ...t on by flipping the toggle switch to the on position The indicator lamp should glow and the unit s drive fan should rotate If either of these do not function refer to the Troubleshooting section with...

Страница 10: ...t is safe for use with the aluminum components in the PCN It is extremely important to thoroughly wipe clean all high voltage insulators whenever the components are cleaned Use a non abrasive cloth to...

Страница 11: ...for replacing an ionizer wire 1 Remove the damaged wire from each spring 2 Replace spring if damaged 3 Loop one end of the new wire over the bottom spring pull down top spring with pliers and loop th...

Страница 12: ...r pack is defective c A dead short exists in the ionizer and or collection cell circuit d Components need cleaning Corrective Action a Replace the bulb b Replace the high voltage power pack c Troubles...

Страница 13: ...d to the components is below a good operating level or the light circuit is not functioning If push to test buttons are not depressed a residual DC voltage will remain on the high voltage components f...

Страница 14: ...remove the side access panel and check out the high voltage power pack See Figure 5 a Remove both high voltage leads from the end of the power pack b Measure high voltage use probe at terminal No 8 ou...

Страница 15: ...o loose causes slippage and reduces airflow Having the belt set too tight causes an over current condition in the motor The resulting higher temperature shortens motor winding and bearing life CAU T I...

Страница 16: ...12 SMOG HOG Electrostatic Precipitator PCN Series 7 Troubleshooting Flowchart...

Страница 17: ...tor Pulley 1 8 31 0102 Blower Pulley 1 9 31 0083 Drive Belt 1 10 17 0010 Wheel 8 2 11 17 0012 Caster 5 Swivel 2 12 03 1000 Short Out Spring Assly 1 13 18 1931 Dust Pan 1 14 20 0326 Toggle Switch 1 15...

Страница 18: ...14 SMOG HOG Electrostatic Precipitator PCN Series 9 Wiring Diagrams...

Страница 19: ...15 SMOG HOG Electrostatic Precipitator PCN Series...

Страница 20: ...n abrasion abnormal use or misuse misapplication or normal wear and tear e Equipment not properly installed operated and maintained under normal conditions and recommended applications As Buyers exclu...

Страница 21: ...Description of troubleshooting effort details 5 Description of physical location and or environment details The Buyer shall cooperate with PARKER in its investigation and provide full information and...

Страница 22: ...en Leur Netherlands 31 76 508 5300 www parker com dhfns Hiross Zander Essen Germany 49 2054 9340 www parker com hzfd Padova Italy 39 049 9712 111 www parker com hzfd Engine Filtration Water Purificati...

Отзывы: