background image

11

SMOG-HOG Electrostatic Precipitator    PCN Series

Figure 5
Power Pack Terminal Connections

5.5  Checking Air Movement (Blower and Drive) 

1.  If the unit has deficient airflow: 

a.  Check for any type of restriction in the pick-up hood, flex hose or main unit. 
b.  Remove the pre-filter, cell and ionizer components and check for an obstruction at the diffuser plate 

directly above them. If none is present, check the components for excessive dirt build up. 

c.  If components are clean, remove the side access panel and check for: 

i.  Loose or broken belt 
ii. Defective drive motor 
iii.  Loose pulley  

 

 
 
The belt should have approximately 1⁄2” of play when depressed with one finger. Having the belt set 
too loose causes slippage and reduces airflow. Having the belt set too tight causes an over current 
condition in the motor. The resulting higher temperature shortens motor winding and bearing life. 

!

 

  C A U T I O N

6.  Replacement Parts

6.1 Ordering Parts 

Replacement parts can be ordered from your local representative or from Parker direct.  
To order parts from Parker, contact Customer Service at 1-800-348-4048. Please have the following 
information available for prompt service: 
1.  Unit model number (on nameplate, blower access door) 
2.  Unit serial number (on nameplate, blower access door) 
3. Part number of part(s) (see parts list)  

6.2 Returning Parts 

When returning a defective part under warranty, you need to call Parker Hannifin for a Return Material 
Authorization (RMA) number. This control number assures you receive prompt service, so it should 
appear prominently on the package being returned.

Содержание Smog-Hog PCN

Страница 1: ...Smog Hog Portable Electrostatic Precipitator Owner s Manual Model PCN...

Страница 2: ...r service have the following information available when contacting Parker Unit Order ___________________________________________________________________ Unit Model ____________________________________...

Страница 3: ...Unit On 3 3 2 Operating the Unit 3 4 Maintenance and Cleaning 4 4 1 Cleaning Schedules 4 4 2 Component Cleaning 4 4 3 Periodic Maintenance 5 4 4 Other Maintenance 5 5 Troubleshooting Guide 6 5 1 How t...

Страница 4: ...om unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage Operate only in a safe and serviceable conditio...

Страница 5: ...of Parker Parker disclaims any liability or responsibility for damage from fires or explosions regardless of origin Parker recommends that all APC dust collection equipment installation and applicati...

Страница 6: ...SMOG HOG Electrostatic Precipitator PCN Series Page intentionally left blank...

Страница 7: ...n attract the particles Air next passes through a centrifugal blower where it is exhausted vertically through an adjustable outlet grille back to the work space An integrally mounted power pack conver...

Страница 8: ...llation and the mounting hardware bolts flat washers and split ring lock washers is in a plastic bag inside the main cabinet The extraction arm assembly is approximately 50 lbs but because of its size...

Страница 9: ...t on by flipping the toggle switch to the on position The indicator lamp should glow and the unit s drive fan should rotate If either of these do not function refer to the Troubleshooting section with...

Страница 10: ...t is safe for use with the aluminum components in the PCN It is extremely important to thoroughly wipe clean all high voltage insulators whenever the components are cleaned Use a non abrasive cloth to...

Страница 11: ...for replacing an ionizer wire 1 Remove the damaged wire from each spring 2 Replace spring if damaged 3 Loop one end of the new wire over the bottom spring pull down top spring with pliers and loop th...

Страница 12: ...r pack is defective c A dead short exists in the ionizer and or collection cell circuit d Components need cleaning Corrective Action a Replace the bulb b Replace the high voltage power pack c Troubles...

Страница 13: ...d to the components is below a good operating level or the light circuit is not functioning If push to test buttons are not depressed a residual DC voltage will remain on the high voltage components f...

Страница 14: ...remove the side access panel and check out the high voltage power pack See Figure 5 a Remove both high voltage leads from the end of the power pack b Measure high voltage use probe at terminal No 8 ou...

Страница 15: ...o loose causes slippage and reduces airflow Having the belt set too tight causes an over current condition in the motor The resulting higher temperature shortens motor winding and bearing life CAU T I...

Страница 16: ...12 SMOG HOG Electrostatic Precipitator PCN Series 7 Troubleshooting Flowchart...

Страница 17: ...tor Pulley 1 8 31 0102 Blower Pulley 1 9 31 0083 Drive Belt 1 10 17 0010 Wheel 8 2 11 17 0012 Caster 5 Swivel 2 12 03 1000 Short Out Spring Assly 1 13 18 1931 Dust Pan 1 14 20 0326 Toggle Switch 1 15...

Страница 18: ...14 SMOG HOG Electrostatic Precipitator PCN Series 9 Wiring Diagrams...

Страница 19: ...15 SMOG HOG Electrostatic Precipitator PCN Series...

Страница 20: ...n abrasion abnormal use or misuse misapplication or normal wear and tear e Equipment not properly installed operated and maintained under normal conditions and recommended applications As Buyers exclu...

Страница 21: ...Description of troubleshooting effort details 5 Description of physical location and or environment details The Buyer shall cooperate with PARKER in its investigation and provide full information and...

Страница 22: ...en Leur Netherlands 31 76 508 5300 www parker com dhfns Hiross Zander Essen Germany 49 2054 9340 www parker com hzfd Padova Italy 39 049 9712 111 www parker com hzfd Engine Filtration Water Purificati...

Отзывы: