4.3 Periodic Maintenance
1. At least every three months (or whenever components are removed for soak cleaning), wipe clean the
ionizer and collection cell contact springs and insulators located above the pre-filter. Clean out the
interior cabinet area.
2. With the PCN unplugged, brush clean all wiring connections at the power pack and switches.
3. Check for drive belt tension and wear. One half inch movement (with finger pressure) at the belt
mid-point indicates correct tension. Refer to Figure 1.
4.4 Other Maintenance
Instructions for replacing an ionizer wire:
1. Remove the damaged wire from each spring.
2. Replace spring if damaged.
3. Loop one end of the new wire over the bottom spring, pull down top spring with pliers and loop the
top end of the wire over the spring hook. Refer to Figure 2.
4. Release the spring gently. The wire is now taut and automatically centered.
Note: In the event replacement wire is not immediately available, remove broken wire and springs from
the assembly to allow operation until new parts can be installed.
The following section is for the use of trained service personnel only. The following procedures will
expose hazardous live and moving parts. Disconnect the air cleaner before proceeding.
!
C A U T I O N
Figure 1
Motor/Blower Assembly
Figure 2
Ionizer Wire/Spring Installation
Содержание Smog-Hog PCN
Страница 1: ...Smog Hog Portable Electrostatic Precipitator Owner s Manual Model PCN...
Страница 6: ...SMOG HOG Electrostatic Precipitator PCN Series Page intentionally left blank...
Страница 16: ...12 SMOG HOG Electrostatic Precipitator PCN Series 7 Troubleshooting Flowchart...
Страница 18: ...14 SMOG HOG Electrostatic Precipitator PCN Series 9 Wiring Diagrams...
Страница 19: ...15 SMOG HOG Electrostatic Precipitator PCN Series...