background image

10

SMOG-HOG Electrostatic Precipitator    PCN Series

1.  Remove the cell and depress the door interlock switch. 

2.  If the indicator light comes on, the problem is in the cell. Check for the following: 

a.  Excessive build up between cell plates. 
b.  Something lodged between the cell plates, bowed or bent plates, etc. 
c.  Cracks in any of the eight cell insulators, carbon tracking or other insulator damage. 

3.  If the indicator light remains off with the cell out of the unit, remove the ionizer and activate the 

power supply. 

4.  If the indicator light comes on, the problem is in the ionizer. Check for the following: 

a.  Broken or loose ionizer wires. 
b.  Excessive build up on insulator(s). 
c.  Cracked or broken insulator(s). 

5.  If the light remains out with both the ionizer and cell removed, remove the side access panel and 

check out the high voltage power pack. See Figure 5. 

a.  Remove both high voltage leads from the end of the power pack. 
b.  Measure high voltage (use probe) at terminal No. 8 (output to ionizer) and terminal No. 7  

(output to collector). 

c.  If no voltage is present or voltage is below minimum, replace the power pack.  

Note: Minimum reading with high voltage wires removed: 11KV at terminal No. 8 (ionizer) and  
5KV at terminal No. 7 (collector).

6.  If voltage is present and within limits, check for: 

a.  Short in the high voltage lead wires. 
b.  Cracked or broken cabinet insulators. 

 

5.4  Determining the Loss of High Voltage 

As components build up dirt, the indicator light 
dims then goes out at a point approximately 
3.5KV cell voltage. If satisfactory operating 
voltage is present at the ionizer and cell and 
the light is out, the problem is either a defective 
indicator light or light circuit. 
If no voltage is present at the cell, and the 
indicator light is out:  

Содержание Smog-Hog PCN

Страница 1: ...Smog Hog Portable Electrostatic Precipitator Owner s Manual Model PCN...

Страница 2: ...r service have the following information available when contacting Parker Unit Order ___________________________________________________________________ Unit Model ____________________________________...

Страница 3: ...Unit On 3 3 2 Operating the Unit 3 4 Maintenance and Cleaning 4 4 1 Cleaning Schedules 4 4 2 Component Cleaning 4 4 3 Periodic Maintenance 5 4 4 Other Maintenance 5 5 Troubleshooting Guide 6 5 1 How t...

Страница 4: ...om unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage Operate only in a safe and serviceable conditio...

Страница 5: ...of Parker Parker disclaims any liability or responsibility for damage from fires or explosions regardless of origin Parker recommends that all APC dust collection equipment installation and applicati...

Страница 6: ...SMOG HOG Electrostatic Precipitator PCN Series Page intentionally left blank...

Страница 7: ...n attract the particles Air next passes through a centrifugal blower where it is exhausted vertically through an adjustable outlet grille back to the work space An integrally mounted power pack conver...

Страница 8: ...llation and the mounting hardware bolts flat washers and split ring lock washers is in a plastic bag inside the main cabinet The extraction arm assembly is approximately 50 lbs but because of its size...

Страница 9: ...t on by flipping the toggle switch to the on position The indicator lamp should glow and the unit s drive fan should rotate If either of these do not function refer to the Troubleshooting section with...

Страница 10: ...t is safe for use with the aluminum components in the PCN It is extremely important to thoroughly wipe clean all high voltage insulators whenever the components are cleaned Use a non abrasive cloth to...

Страница 11: ...for replacing an ionizer wire 1 Remove the damaged wire from each spring 2 Replace spring if damaged 3 Loop one end of the new wire over the bottom spring pull down top spring with pliers and loop th...

Страница 12: ...r pack is defective c A dead short exists in the ionizer and or collection cell circuit d Components need cleaning Corrective Action a Replace the bulb b Replace the high voltage power pack c Troubles...

Страница 13: ...d to the components is below a good operating level or the light circuit is not functioning If push to test buttons are not depressed a residual DC voltage will remain on the high voltage components f...

Страница 14: ...remove the side access panel and check out the high voltage power pack See Figure 5 a Remove both high voltage leads from the end of the power pack b Measure high voltage use probe at terminal No 8 ou...

Страница 15: ...o loose causes slippage and reduces airflow Having the belt set too tight causes an over current condition in the motor The resulting higher temperature shortens motor winding and bearing life CAU T I...

Страница 16: ...12 SMOG HOG Electrostatic Precipitator PCN Series 7 Troubleshooting Flowchart...

Страница 17: ...tor Pulley 1 8 31 0102 Blower Pulley 1 9 31 0083 Drive Belt 1 10 17 0010 Wheel 8 2 11 17 0012 Caster 5 Swivel 2 12 03 1000 Short Out Spring Assly 1 13 18 1931 Dust Pan 1 14 20 0326 Toggle Switch 1 15...

Страница 18: ...14 SMOG HOG Electrostatic Precipitator PCN Series 9 Wiring Diagrams...

Страница 19: ...15 SMOG HOG Electrostatic Precipitator PCN Series...

Страница 20: ...n abrasion abnormal use or misuse misapplication or normal wear and tear e Equipment not properly installed operated and maintained under normal conditions and recommended applications As Buyers exclu...

Страница 21: ...Description of troubleshooting effort details 5 Description of physical location and or environment details The Buyer shall cooperate with PARKER in its investigation and provide full information and...

Страница 22: ...en Leur Netherlands 31 76 508 5300 www parker com dhfns Hiross Zander Essen Germany 49 2054 9340 www parker com hzfd Padova Italy 39 049 9712 111 www parker com hzfd Engine Filtration Water Purificati...

Отзывы: