background image

8

SMOG-HOG Electrostatic Precipitator    PCN Series

5. Troubleshooting Guide 

Tools Required 

1. Screwdriver: 8˝ or longer with insulated handle.
2.  Volt-Ohmmeter: used to check low voltage input (120 VAC) and continuity (OHMS). 
3.  High Voltage Probe: used to check high voltage power supply, minimum range from 0-15 KVDC. 
* Refer also to the Troubleshooting Flow Chart on page 10. 

 

Normal Operation 

1.  Turning the toggle switch on allows power supply to the blower and high voltage power pack  

(see Wiring Diagram, page 12). 

2.  The indicator light is on, and its glow is bright and steady, indicating high voltage is present at the power pack. 
3.  Air draw through the welding hood to the PCN unit is adequate. 
4. Unit is clean.  

Abnormal Operation 

1.  The indicator light is off even though the unit blower is running. 

Possible Cause: 
a.  The light bulb is burnt out. 
b.  The high voltage power pack is defective. 
c.  A dead short exists in the ionizer and/or collection cell circuit. 
d.  Components need cleaning. 
Corrective Action: 
a. Replace the bulb. 
b. Replace the high voltage power pack. 
c.  Troubleshoot and remove the short (see how to troubleshoot ionizer and cell circuit, page 7). 
d. Remove components and clean. 

 

2.  Indicator light is flickering on/off with audible arcing inside the cabinet.  

Possible Cause: 

a.  An intermittent short exists in the ionizer and/or cell circuit. 
b.  Components need cleaning. 
Corrective Action: 
a. Remove the ionizer and cell, inspect for the cause.
b. Remove components and clean.  

3.  The indicator light is on but the unit does not have adequate air movement.  

Possible Cause: 
a. The drive belt is loose or off the pulley. 
b. The drive motor has malfunctioned. 
c. The hood throat screen has plugged. 
d. Components need cleaning.  
e. The diffuser screen has plugged. 
Corrective Action: 
a. Tighten or replace the belt. 
b.  Repair or replace the motor. 
c.  Remove the blockage from the screen. 
d.  Remove and clean the components. 
e. Clean the diffuser screen. 

 

Содержание Smog-Hog PCN

Страница 1: ...Smog Hog Portable Electrostatic Precipitator Owner s Manual Model PCN...

Страница 2: ...r service have the following information available when contacting Parker Unit Order ___________________________________________________________________ Unit Model ____________________________________...

Страница 3: ...Unit On 3 3 2 Operating the Unit 3 4 Maintenance and Cleaning 4 4 1 Cleaning Schedules 4 4 2 Component Cleaning 4 4 3 Periodic Maintenance 5 4 4 Other Maintenance 5 5 Troubleshooting Guide 6 5 1 How t...

Страница 4: ...om unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage Operate only in a safe and serviceable conditio...

Страница 5: ...of Parker Parker disclaims any liability or responsibility for damage from fires or explosions regardless of origin Parker recommends that all APC dust collection equipment installation and applicati...

Страница 6: ...SMOG HOG Electrostatic Precipitator PCN Series Page intentionally left blank...

Страница 7: ...n attract the particles Air next passes through a centrifugal blower where it is exhausted vertically through an adjustable outlet grille back to the work space An integrally mounted power pack conver...

Страница 8: ...llation and the mounting hardware bolts flat washers and split ring lock washers is in a plastic bag inside the main cabinet The extraction arm assembly is approximately 50 lbs but because of its size...

Страница 9: ...t on by flipping the toggle switch to the on position The indicator lamp should glow and the unit s drive fan should rotate If either of these do not function refer to the Troubleshooting section with...

Страница 10: ...t is safe for use with the aluminum components in the PCN It is extremely important to thoroughly wipe clean all high voltage insulators whenever the components are cleaned Use a non abrasive cloth to...

Страница 11: ...for replacing an ionizer wire 1 Remove the damaged wire from each spring 2 Replace spring if damaged 3 Loop one end of the new wire over the bottom spring pull down top spring with pliers and loop th...

Страница 12: ...r pack is defective c A dead short exists in the ionizer and or collection cell circuit d Components need cleaning Corrective Action a Replace the bulb b Replace the high voltage power pack c Troubles...

Страница 13: ...d to the components is below a good operating level or the light circuit is not functioning If push to test buttons are not depressed a residual DC voltage will remain on the high voltage components f...

Страница 14: ...remove the side access panel and check out the high voltage power pack See Figure 5 a Remove both high voltage leads from the end of the power pack b Measure high voltage use probe at terminal No 8 ou...

Страница 15: ...o loose causes slippage and reduces airflow Having the belt set too tight causes an over current condition in the motor The resulting higher temperature shortens motor winding and bearing life CAU T I...

Страница 16: ...12 SMOG HOG Electrostatic Precipitator PCN Series 7 Troubleshooting Flowchart...

Страница 17: ...tor Pulley 1 8 31 0102 Blower Pulley 1 9 31 0083 Drive Belt 1 10 17 0010 Wheel 8 2 11 17 0012 Caster 5 Swivel 2 12 03 1000 Short Out Spring Assly 1 13 18 1931 Dust Pan 1 14 20 0326 Toggle Switch 1 15...

Страница 18: ...14 SMOG HOG Electrostatic Precipitator PCN Series 9 Wiring Diagrams...

Страница 19: ...15 SMOG HOG Electrostatic Precipitator PCN Series...

Страница 20: ...n abrasion abnormal use or misuse misapplication or normal wear and tear e Equipment not properly installed operated and maintained under normal conditions and recommended applications As Buyers exclu...

Страница 21: ...Description of troubleshooting effort details 5 Description of physical location and or environment details The Buyer shall cooperate with PARKER in its investigation and provide full information and...

Страница 22: ...en Leur Netherlands 31 76 508 5300 www parker com dhfns Hiross Zander Essen Germany 49 2054 9340 www parker com hzfd Padova Italy 39 049 9712 111 www parker com hzfd Engine Filtration Water Purificati...

Отзывы: