5
SMOG-HOG Electrostatic Precipitator PCN Series
3. Operation
Do not use the PCN where high concentrations of flammable materials may be present.
If in doubt, consult Parker.
3.1 Turning the Unit On
The PCN is provided with 10´ of pre-wired type 3-SJ electrical cord with a three-prong male plug.
To operate the unit:
1. Plug the unit into a grounded 115V/1/60 Hz electrical receptacle.
2. For 3-phase units please refer to wiring diagram.
3. Lock wheel casters on unit to secure location.
Do not attempt to move the PCN unit by pulling on the extraction arm or hood.
Use handles on the back of the unit to pull the PCN around the work area.
4. Turn the unit on by flipping the toggle switch to the “on” position. The indicator lamp should glow, and
the unit’s drive fan should rotate. If either of these do not function, refer to the Troubleshooting section
within this manual.
5. The unit is now ready for use.
3.2 Operating the Unit
The PCN moves 1,000 CFM of contaminated air away from the source of generation.
For good contaminant capture, a few simple guidelines apply:
1. Locate the unit, arm and hood in anticipation of the job(s) intended. Know the limitations of the unit
and the job.
2. Minimize the influence of cross drafts from outside air sources.
3. Position the hood slightly higher than the source, with the face of the hood approximately 45° from
horizontal. The hood shape is designed for high velocity pick-up. It should be located no further than
18˝ from the contaminant source.
!
C A U T I O N
!
C A U T I O N
Содержание Smog-Hog PCN
Страница 1: ...Smog Hog Portable Electrostatic Precipitator Owner s Manual Model PCN...
Страница 6: ...SMOG HOG Electrostatic Precipitator PCN Series Page intentionally left blank...
Страница 16: ...12 SMOG HOG Electrostatic Precipitator PCN Series 7 Troubleshooting Flowchart...
Страница 18: ...14 SMOG HOG Electrostatic Precipitator PCN Series 9 Wiring Diagrams...
Страница 19: ...15 SMOG HOG Electrostatic Precipitator PCN Series...