SLVDN User’s Manual
Page 80 of 181
Par. Descrption
Field
Def.
b99.10
Command to reset alarms.
This command sets Pr23 and Pr24 to 0.
If the alarm continues, it is displayed on the screen. This command
cannot be used if there is a check-sum error (Pr23 = 10, 11). In this
case, it is necessary to set the default parameters (b99.12) and then
reset the alarm.
R/W 0
b99.11
Default values of the parameters in operating mode
. This
command sets the operating mode parameters to the default values.
The command is executed only if b40.2 = 0.
R/W 0
b99.12
Default values.
This command sets all parameters to the default
values and sets those used by the operating mode to 0. Furthermore,
it sets the pico-PLC program as described in
Appendix
. There is a
check-sum alarm, Pr23 and Pr24 will be set to 0, thereby permitting
the alarm to be reset. The command is executed only if b99.13 = 0.
R/W
M
0
b99.13
Status of the pico-PLC.
If set to 1, the PLC program is executed. If
set to 0, the pico-PLC is in stop and the PLC instructions can be
modified.
R/W
M
1
b99.14
Storing of the pico-PLC instructions.
This command saves the
pico-PLC program. It cannot be used if a check-sum alarm has been
indicated. In this case, it is necessary to set the default parameters,
reset the alarm and then store the new parameters.
R/W 0
b99.15
Storing of parameters.
This command stores all parameters. It
cannot be used if a check-sum alarm has been indicated. In this case,
it is necessary to set the default parameters, reset the alarm and then
store the new parameters.
R/W 0
b231.1
Set encoder pulses as exponent on base 2.
This bit decides the
format of Pr196 parameter.
R/W 0
b231.2
Multiturn position read.
(1) if multiturn absolute position is read at
start up
R/W 0
b231.3
IEC 61131 automatic memory extension.
(1) the pico-PLC is
disabled b99.13=0), the all instructions of the pico-PLC (512 byte)
are used as automatic variables for the IEC 61131 programming
language.
R/W 0
b231.5
Time out pico-PLC.
R/W 0
b231.10
(1) enable profiles on TAB0.
Motor control PWM (0) 8 kHz – (1) 4 kHz [except SLVD17N].
If
=1, the first time the drive is powered on again PWM at 4Khz is
enabled. (The setting is enabled at the next power on ).
0
b231.11
Motor control PWM (0) 8 kHz – (1) 4 kHz [only SLVD17N].
If
=0, the first time the drive is powered on again PWM at 8Khz is
enabled, the drive peak currents is limited to 90% (30Arms). (Pr35 –
90%). (The setting is enabled at the next power on ).
R/W
1
b231.12
PTC motor pre-alarm (1).
This pre-alarm allows to stop the
machine before (around 125°C – 257°F) reaching the alarm limit
(around 135°C – 275°F).
R 0
b231.15
Enable IEC 61131.
(1) Start. (0) Stop
R/W 0
Содержание SLVD1N
Страница 7: ...Parker Hannifin S p A S B C Division SLVDN User s Manual Page 7 of 181 ...
Страница 22: ...Parker Hannifin S p A S B C Division SLVDN User s Manual Page 22 of 181 ...
Страница 23: ...Parker Hannifin S p A S B C Division SLVDN User s Manual Page 23 of 181 ...
Страница 34: ...Parker Hannifin S p A S B C Division SLVDN User s Manual Page 34 of 181 5 6 Motor connection diagrams ...
Страница 35: ...Parker Hannifin S p A S B C Division SLVDN User s Manual Page 35 of 181 5 7 Resolver connection diagrams ...
Страница 36: ...Parker Hannifin S p A S B C Division SLVDN User s Manual Page 36 of 181 5 8 Encoder connection ...
Страница 181: ......