If I
2
t current clamping is active bit 11 of the statusword rises.
13.1.2.1.
Object 6040h: Controlword
The
controlword
consist of bits for:
• the controlling of the state,
• the controlling of operating modes and
• manufacturer specific options. OBJECT DESCRIPTION
start
Not ready to
switch On
Switch On
disabled
Ready to
Switch On
Switched On
Operation enable
Fault reaction
active
Fault
Quick stop active
0
1
2
7
3
6
4
5
11
16
8
9
10
12
15
14
13
Power disable
Fault
Power enable