Installation
4-36
AC30 series Variable Speed Inverter
APPLICATION 5: ACTIVE FRONT-END
Application 5:
“AFE”
ACTIVE FRONT END APPLICATION THAT ALLOWS THE
DRIVE TO PERFORM REGENERATION OF ENERGY BACK
INTO THE GRID, AND EXECUTES CONTROL OF
EXTERNAL PRECHARGE SWITCHES AND CONTACTORS
M
AFE Drive
Motoring Drive
Grid
Motor
AFE Control Application
A simple application that controls external precharge relays and contactors, and ensures that all pre-requisites for regenerative operation of the
drive are satisfied. If the drive is used as an active front end this application MUST be loaded and enabled. If the shown control wiring to the
control card terminals is correct no further modification to the application is needed to be able to run in AFE mode. (The line sync card needs to
be wired to the encoder option too.)
Содержание LINKnet AC30P
Страница 47: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Страница 49: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Страница 51: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Страница 53: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Страница 55: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Страница 57: ...4 37 Installation AC30 series Variable Speed Inverter AFE Control Wiring Excludes 7004 04 00 Wiring...
Страница 152: ...9 27 Setup Wizard AC30 series Variable Speed Inverter MONITOR THE DRIVE Figure 9 15 Monitor the Drive and fine tune...
Страница 153: ...Setup Wizard 9 28 AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Страница 161: ...10 8 Trips Fault Finding AC30 series Variable Speed Inverter...